Analysis of the uncertainties in the dose audit system using radiophotoluminescent glass dosimeters in Japanese radiotherapy units

https://repo.qst.go.jp/records/86176
https://repo.qst.go.jp/records/86176
7cb8d281-1d24-478d-a4bd-07dd0d0c7719
Item type 学術雑誌論文 / Journal Article(1)
公開日 2022-04-04
タイトル
タイトル Analysis of the uncertainties in the dose audit system using radiophotoluminescent glass dosimeters in Japanese radiotherapy units
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hideyuki, Mizuno

× Hideyuki, Mizuno

WEKO 1052553

Hideyuki, Mizuno

Search repository
Wataru, Yamashita

× Wataru, Yamashita

WEKO 1052554

Wataru, Yamashita

Search repository
Nobuhiro, Takase

× Nobuhiro, Takase

WEKO 1052555

Nobuhiro, Takase

Search repository
Taku, Nakaji

× Taku, Nakaji

WEKO 1052556

Taku, Nakaji

Search repository
Shigekazu, Fukuda

× Shigekazu, Fukuda

WEKO 1052557

Shigekazu, Fukuda

Search repository
Okuyama, Hiroaki

× Okuyama, Hiroaki

WEKO 1052558

Okuyama, Hiroaki

Search repository
Hideyuki, Mizuno

× Hideyuki, Mizuno

WEKO 1052559

en Hideyuki, Mizuno

Search repository
Wataru, Yamashita

× Wataru, Yamashita

WEKO 1052560

en Wataru, Yamashita

Search repository
Nobuhiro, Takase

× Nobuhiro, Takase

WEKO 1052561

en Nobuhiro, Takase

Search repository
Taku, Nakaji

× Taku, Nakaji

WEKO 1052562

en Taku, Nakaji

Search repository
Shigekazu, Fukuda

× Shigekazu, Fukuda

WEKO 1052563

en Shigekazu, Fukuda

Search repository
抄録
内容記述タイプ Abstract
内容記述 A dosimetry audit of radiotherapy units in Japan was performed using
radiophotoluminescent glass dosimeters (RPLDs). This study analyses the
uncertainties associated with the procedure for determining the absorbed dose by an
RPLD from a high-energy photon beam in radiotherapy units. The absorbed dose is
derived using six parameters: the indicated value given by the RPLD, the individual
dosimeter sensitivity correction factor for each element, the calibration coefficient for
the reference radiation quality, the correction factor for the radiation quality, the
correction factor for the phantom material, and the correction factor of nonlinearity. The
uncertainty of each parameter was estimated based on the ISO standard methodology,
“Guide to the Expression of Uncertainty in Measurement.” The estimated combined
standard uncertainty of the dose measured by RPLD was 1.4% under the reference
condition. This value was compared to the standard deviation of the difference
between the measured and intended doses obtained from the actual audit results
(4,447 beams from 577 hospitals) over 13 years. The average percentage difference
between the measured and calculated doses under the reference condition was 0.4%,
with a standard deviation (k=1) of 1.3%. The results were consistent with the
uncertainty estimated by this report and demonstrate the reliability of the RPLD
dosimetry method.
書誌情報 Radiation Measurements

巻 153, p. 106753, 発行日 2022-04
出版者
出版者 Elsevier B.V.
ISSN
収録物識別子タイプ ISSN
収録物識別子 1350-4487
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radmeas.2022.106753
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S1350448722000488
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:48:56.882069
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3