{"_buckets": {"deposit": "5e217424-3446-4f8b-8dac-ae23573236bc"}, "_deposit": {"created_by": 1, "id": "85056", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "85056"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00085056", "sets": ["28"]}, "author_link": ["1025723", "1025724", "1025721", "1025725", "1025720", "1025719", "1025722", "1025718"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2022-03-01", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Natural uranium comprises of three natural isotopes such as 238U, 235U and 234U with relative isotopic abundances of 99.27%, 0.72% and 0.0055%, respectively. The concentration of uranium in Japanese rivers water ranged from 0.13 to 590 pg mL-1 with a mean value of 54.7 pg mL-1, which is three magnitudes lower than World Health Organization (WHO) recommended value (30 µgL-1). Hence, the isotope ratios measurement of 234U/238U and 235U/238U in low concentrated water samples is a challenging task. \nThe 234U/238U and 235U/238U isotope ratios were measured using a multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS). The combination of 1012 Ohm resistor Faraday cup and Daly detectors are used for low abundance of 234U measurement. A standard solution containing 50 pg mL-1 of U was selected for accuracy and precision measurement of 234U/238U and 235U/238U isotope ratios. MC-ICP-MS coupled with desolvating nebulizer system could measure U isotope ratios at picogram level in ground water, river water, pond water and stream water from Fukushima prefecture. The DGA-normal extraction chromatography resin was used for the chemical separation of U from other elements in water samples. Further data will be present during presentation.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "福島大学環境放射能研究所第8回成果報告会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Murugan, Rajamanickam"}], "nameIdentifiers": [{"nameIdentifier": "1025718", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kavasi, Norbert"}], "nameIdentifiers": [{"nameIdentifier": "1025719", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sahoo, Sarata"}], "nameIdentifiers": [{"nameIdentifier": "1025720", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tatsuo, Aono"}], "nameIdentifiers": [{"nameIdentifier": "1025721", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murugan, Rajamanickam", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1025722", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kavasi, Norbert", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1025723", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sahoo, Sarata", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1025724", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tatsuo, Aono", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1025725", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Accurate measurement of 234U/238U and 235U/238U isotope ratio in water samples at picogram level using multi collector inductively couple plasma mass spectrometry", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Accurate measurement of 234U/238U and 235U/238U isotope ratio in water samples at picogram level using multi collector inductively couple plasma mass spectrometry"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/85056", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-01-13"}, "publish_date": "2022-01-13", "publish_status": "0", "recid": "85056", "relation": {}, "relation_version_is_last": true, "title": ["Accurate measurement of 234U/238U and 235U/238U isotope ratio in water samples at picogram level using multi collector inductively couple plasma mass spectrometry"], "weko_shared_id": -1}
Accurate measurement of 234U/238U and 235U/238U isotope ratio in water samples at picogram level using multi collector inductively couple plasma mass spectrometry
https://repo.qst.go.jp/records/85056
https://repo.qst.go.jp/records/85056203d56c6-1b39-47bc-a1ac-fbd82294560e
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-01-13 | |||||
タイトル | ||||||
タイトル | Accurate measurement of 234U/238U and 235U/238U isotope ratio in water samples at picogram level using multi collector inductively couple plasma mass spectrometry | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Murugan, Rajamanickam
× Murugan, Rajamanickam× Kavasi, Norbert× Sahoo, Sarata× Tatsuo, Aono× Murugan, Rajamanickam× Kavasi, Norbert× Sahoo, Sarata× Tatsuo, Aono |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Natural uranium comprises of three natural isotopes such as 238U, 235U and 234U with relative isotopic abundances of 99.27%, 0.72% and 0.0055%, respectively. The concentration of uranium in Japanese rivers water ranged from 0.13 to 590 pg mL-1 with a mean value of 54.7 pg mL-1, which is three magnitudes lower than World Health Organization (WHO) recommended value (30 µgL-1). Hence, the isotope ratios measurement of 234U/238U and 235U/238U in low concentrated water samples is a challenging task. The 234U/238U and 235U/238U isotope ratios were measured using a multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS). The combination of 1012 Ohm resistor Faraday cup and Daly detectors are used for low abundance of 234U measurement. A standard solution containing 50 pg mL-1 of U was selected for accuracy and precision measurement of 234U/238U and 235U/238U isotope ratios. MC-ICP-MS coupled with desolvating nebulizer system could measure U isotope ratios at picogram level in ground water, river water, pond water and stream water from Fukushima prefecture. The DGA-normal extraction chromatography resin was used for the chemical separation of U from other elements in water samples. Further data will be present during presentation. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 福島大学環境放射能研究所第8回成果報告会 | |||||
発表年月日 | ||||||
日付 | 2022-03-01 | |||||
日付タイプ | Issued |