{"_buckets": {"deposit": "153fc4ae-ba71-4361-82bb-a74a768aa582"}, "_deposit": {"created_by": 1, "id": "84950", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "84950"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00084950", "sets": ["1"]}, "author_link": ["1043386", "1043388", "1043393", "1043387", "1043391", "1043394", "1043395", "1043389", "1043392", "1043390", "1043385", "1043383", "1043384"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2022-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "e81", "bibliographicPageStart": "e50", "bibliographicVolumeNumber": "49", "bibliographic_titles": [{"bibliographic_title": "Medical Physics"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Dose uncertainty induced by respiratory motion remains a major concern for treating thoracic and abdominal lesions using particle beams. This Task Group report reviews the impact of tumor motion and dosimetric considerations in particle radiotherapy, current motion-management techniques, and limitations for different particle-beam delivery modes (i.e., passive scattering, uniform scanning, and pencil-beam scanning). Furthermore, the report provides guidance and risk analysis for quality assurance of the motion-management procedures to ensure consistency and accuracy, and discusses future development and emerging motion-management strategies. This report supplements previously published AAPM report TG76, and considers aspects of motion management that are crucial to the accurate and safe delivery of particle-beam therapy. To that end, this report produces general recommendations for commissioning and facility-specific dosimetric characterization, motion assessment, treatment planning, active and passive motion-management techniques, image guidance and related decision-making, monitoring throughout therapy, and recommendations for vendors. Key among these recommendations are that: 1) facilities should perform thorough planning studies (using retrospective data) and develop standard operating procedures that address all aspects of therapy for any treatment site involving respiratory motion; 2) a risk-based methodology should be adopted for quality management and ongoing process improvement.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Wiley"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1002/mp.15470", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.15470", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0094-2405", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Li, Heng"}], "nameIdentifiers": [{"nameIdentifier": "1043383", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Dong, Lei"}], "nameIdentifiers": [{"nameIdentifier": "1043384", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Christoph Bert"}], "nameIdentifiers": [{"nameIdentifier": "1043385", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Joe Chang"}], "nameIdentifiers": [{"nameIdentifier": "1043386", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Stella Flampouri"}], "nameIdentifiers": [{"nameIdentifier": "1043387", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kyung-Wook Jee"}], "nameIdentifiers": [{"nameIdentifier": "1043388", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Liyong Lin"}], "nameIdentifiers": [{"nameIdentifier": "1043389", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Moyers, Michael"}], "nameIdentifiers": [{"nameIdentifier": "1043390", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shinichiro, Mori"}], "nameIdentifiers": [{"nameIdentifier": "1043391", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Joerg Rottmann"}], "nameIdentifiers": [{"nameIdentifier": "1043392", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Erik Tryggestad"}], "nameIdentifiers": [{"nameIdentifier": "1043393", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Vedam, Sastry"}], "nameIdentifiers": [{"nameIdentifier": "1043394", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shinichiro, Mori", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1043395", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Report of AAPM Task Group 290: Respiratory motion management for particle therapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Report of AAPM Task Group 290: Respiratory motion management for particle therapy"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/84950", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-01-27"}, "publish_date": "2022-01-27", "publish_status": "0", "recid": "84950", "relation": {}, "relation_version_is_last": true, "title": ["Report of AAPM Task Group 290: Respiratory motion management for particle therapy"], "weko_shared_id": -1}
Report of AAPM Task Group 290: Respiratory motion management for particle therapy
https://repo.qst.go.jp/records/84950
https://repo.qst.go.jp/records/8495047322b38-c030-4052-addf-dd4206edbf47
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-01-27 | |||||
タイトル | ||||||
タイトル | Report of AAPM Task Group 290: Respiratory motion management for particle therapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Li, Heng
× Li, Heng× Dong, Lei× Christoph Bert× Joe Chang× Stella Flampouri× Kyung-Wook Jee× Liyong Lin× Moyers, Michael× Shinichiro, Mori× Joerg Rottmann× Erik Tryggestad× Vedam, Sastry× Shinichiro, Mori |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Dose uncertainty induced by respiratory motion remains a major concern for treating thoracic and abdominal lesions using particle beams. This Task Group report reviews the impact of tumor motion and dosimetric considerations in particle radiotherapy, current motion-management techniques, and limitations for different particle-beam delivery modes (i.e., passive scattering, uniform scanning, and pencil-beam scanning). Furthermore, the report provides guidance and risk analysis for quality assurance of the motion-management procedures to ensure consistency and accuracy, and discusses future development and emerging motion-management strategies. This report supplements previously published AAPM report TG76, and considers aspects of motion management that are crucial to the accurate and safe delivery of particle-beam therapy. To that end, this report produces general recommendations for commissioning and facility-specific dosimetric characterization, motion assessment, treatment planning, active and passive motion-management techniques, image guidance and related decision-making, monitoring throughout therapy, and recommendations for vendors. Key among these recommendations are that: 1) facilities should perform thorough planning studies (using retrospective data) and develop standard operating procedures that address all aspects of therapy for any treatment site involving respiratory motion; 2) a risk-based methodology should be adopted for quality management and ongoing process improvement. | |||||
書誌情報 |
Medical Physics 巻 49, 号 4, p. e50-e81, 発行日 2022-01 |
|||||
出版者 | ||||||
出版者 | Wiley | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0094-2405 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1002/mp.15470 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.15470 |