WEKO3
アイテム
{"_buckets": {"deposit": "f3e95a94-1c34-46b5-bca0-0c769b7c6ae4"}, "_deposit": {"created_by": 1, "id": "83394", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "83394"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00083394", "sets": ["1"]}, "author_link": ["1063790", "1063786", "1063791", "1063782", "1063788", "1063780", "1063785", "1063783", "1063789", "1063781", "1063787", "1063784"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-09", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "17933", "bibliographicVolumeNumber": "11", "bibliographic_titles": [{"bibliographic_title": "Scientific reports"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Positron-emission tomography (PET) and single-photon-emission computed tomography (SPECT) are well-established nuclear-medicine imaging methods used in modern medical diagnoses. Combining PET with 18F-fuorodeoxyglucose (FDG) and SPECT with an 111In-labelled ligand provides clinicians with information about the aggressiveness and specifc types of tumors. However, it is difcult to integrate a SPECT system with a PET system because SPECT requires a collimator. Herein, we describe a novel method that provides simultaneous imaging with PET and SPECT nuclides by combining PET imaging and Compton imaging. The latter is an imaging method that utilizes Compton scattering to visualize gamma rays over a wide range of energies without requiring a collimator. Using Compton imaging with SPECT nuclides, instead of the conventional SPECT imaging method, enables PET imaging and Compton imaging to be performed with one system. In this research, we havedemonstrated simultaneous in vivo imaging of a tumor-bearing mouse injected with 18F-FDG and an 111In-antibody by using a prototype Compton-PET hybrid camera. We have succeeded in visualizing accumulations \nof 18F-FDG and 111In-antibody by performing PET imaging and Compton imaging simultaneously. As simultaneous imaging utilizes the same coordinate axes, it is expected to improve the accuracy of diagnoses.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1038/s41598-021-97302-7", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.nature.com/articles/s41598-021-97302-7", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2045-2322", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Uenomachi, Mizuki"}], "nameIdentifiers": [{"nameIdentifier": "1063780", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miwako, Takahashi"}], "nameIdentifiers": [{"nameIdentifier": "1063781", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shimazoe, Kenji"}], "nameIdentifiers": [{"nameIdentifier": "1063782", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takahashi, Hiroyuki"}], "nameIdentifiers": [{"nameIdentifier": "1063783", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kamada, Kei"}], "nameIdentifiers": [{"nameIdentifier": "1063784", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Orita, Tadashi"}], "nameIdentifiers": [{"nameIdentifier": "1063785", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ogane, Kenichiro"}], "nameIdentifiers": [{"nameIdentifier": "1063786", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Atsushi, Tsuji"}], "nameIdentifiers": [{"nameIdentifier": "1063787", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mizuki, Uenomachi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1063788", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miwako, Takahashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1063789", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kenji, Shimazoe", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1063790", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Atsushi, Tsuji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1063791", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Simultaneous in vivo imaging with PET and SPECT tracers using a Compton-PET hybrid camera", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Simultaneous in vivo imaging with PET and SPECT tracers using a Compton-PET hybrid camera"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/83394", "pubdate": {"attribute_name": "公開日", "attribute_value": "2021-09-10"}, "publish_date": "2021-09-10", "publish_status": "0", "recid": "83394", "relation": {}, "relation_version_is_last": true, "title": ["Simultaneous in vivo imaging with PET and SPECT tracers using a Compton-PET hybrid camera"], "weko_shared_id": -1}
Simultaneous in vivo imaging with PET and SPECT tracers using a Compton-PET hybrid camera
https://repo.qst.go.jp/records/83394
https://repo.qst.go.jp/records/8339491a9a804-03e1-45f8-844b-82370dc8ce6e
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-09-10 | |||||
タイトル | ||||||
タイトル | Simultaneous in vivo imaging with PET and SPECT tracers using a Compton-PET hybrid camera | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Uenomachi, Mizuki
× Uenomachi, Mizuki× Miwako, Takahashi× Shimazoe, Kenji× Takahashi, Hiroyuki× Kamada, Kei× Orita, Tadashi× Ogane, Kenichiro× Atsushi, Tsuji× Mizuki, Uenomachi× Miwako, Takahashi× Kenji, Shimazoe× Atsushi, Tsuji |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Positron-emission tomography (PET) and single-photon-emission computed tomography (SPECT) are well-established nuclear-medicine imaging methods used in modern medical diagnoses. Combining PET with 18F-fuorodeoxyglucose (FDG) and SPECT with an 111In-labelled ligand provides clinicians with information about the aggressiveness and specifc types of tumors. However, it is difcult to integrate a SPECT system with a PET system because SPECT requires a collimator. Herein, we describe a novel method that provides simultaneous imaging with PET and SPECT nuclides by combining PET imaging and Compton imaging. The latter is an imaging method that utilizes Compton scattering to visualize gamma rays over a wide range of energies without requiring a collimator. Using Compton imaging with SPECT nuclides, instead of the conventional SPECT imaging method, enables PET imaging and Compton imaging to be performed with one system. In this research, we havedemonstrated simultaneous in vivo imaging of a tumor-bearing mouse injected with 18F-FDG and an 111In-antibody by using a prototype Compton-PET hybrid camera. We have succeeded in visualizing accumulations of 18F-FDG and 111In-antibody by performing PET imaging and Compton imaging simultaneously. As simultaneous imaging utilizes the same coordinate axes, it is expected to improve the accuracy of diagnoses. |
|||||
書誌情報 |
Scientific reports 巻 11, p. 17933, 発行日 2021-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2045-2322 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1038/s41598-021-97302-7 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.nature.com/articles/s41598-021-97302-7 |