アイテム

  1. 原著論文

An Improved Passive CR-39-Based Direct 222Rn/220Rn

https://repo.qst.go.jp/records/81069
https://repo.qst.go.jp/records/81069
3663a31b-5ab5-45ed-be17-90f7844ab1c8
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-11-20
タイトル
タイトル An Improved Passive CR-39-Based Direct 222Rn/220Rn
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hu, Jun

× Hu, Jun

WEKO 1013824

Hu, Jun

Search repository
Guosheng Yang

× Guosheng Yang

WEKO 1013825

Guosheng Yang

Search repository
Kranrod, Chutima

× Kranrod, Chutima

WEKO 1013826

Kranrod, Chutima

Search repository
Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 1013827

Iwaoka, Kazuki

Search repository
Hosoda, Masahiro

× Hosoda, Masahiro

WEKO 1013828

Hosoda, Masahiro

Search repository
Tokonami, Shinji

× Tokonami, Shinji

WEKO 1013829

Tokonami, Shinji

Search repository
Yang, Guosheng

× Yang, Guosheng

WEKO 1013830

en Yang, Guosheng

Search repository
Kazuki, Iwaoka

× Kazuki, Iwaoka

WEKO 1013831

en Kazuki, Iwaoka

Search repository
抄録
内容記述タイプ Abstract
内容記述 An improved passive CR-39-based direct 222Rn/220Rn progeny detector with 3 detection channels was designed and tested in this study to measure and calculate equilibrium equivalent concentration (EEC) of both 222Rn and 220Rn without the equilibrium factor. A theoretical model was established to calculate the EEC with optimization. Subsequently, an exposure experiment was carried out to test the performance of this detector, and we compared the chamber experiment and the theoretical model by estimating and measuring various parameters. The deposition flux of progeny derived from the prediction agreed well with the value measured in the exposure chamber. The energy-weighted net track density (NTD) measured by this detector is much more reliable to reflect the linear relation between NTD and time-integrated EEC. Since the detector is sensitive to the exposure environmental condition, it is recommended to apply the detector to measure the EEC after its calibration in a typical indoor environment.
書誌情報 International Journal of Environmental Research and Public Health

巻 17, 号 22, p. 8569, 発行日 2020-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 1660-4601
DOI
識別子タイプ DOI
関連識別子 10.3390/ijerph17228569
関連サイト
識別子タイプ URI
関連識別子 https://www.mdpi.com/1660-4601/17/22/8569
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:17:49.071191
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3