{"_buckets": {"deposit": "daa29bbc-5c66-4a40-9bae-25e57c54655a"}, "_deposit": {"created_by": 1, "id": "80878", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "80878"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00080878", "sets": ["2"]}, "author_link": ["930834", "930832", "930833"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-11", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "325", "bibliographicPageStart": "320", "bibliographic_titles": [{"bibliographic_title": "Proceedings of SNA+MC2020"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We found out that probability table (p-table) data for heating number in the FENDL-3.1d ACE files for 33 nuclei included negative values. Thus we investigated its reason in detail. As a result, it was specified that the reason was that partial KERMA factors of the radiative capture reaction became too large, because the energy-balance was broken or NJOY did not treat secondary gammas of a special format. We proposed two solutions for this issue; 1) to modify NJOY so as to calculate partial KERMA factors with the kinematics method, 2) to set p-tables for heating number to “1.0” or average heating numbers. New ACE files of FENDL-3.1d produced with the two solutions had no negative p-tables for heating number.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Konno, Chikara"}], "nameIdentifiers": [{"nameIdentifier": "930832", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kwon, Saerom"}], "nameIdentifiers": [{"nameIdentifier": "930833", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kwon, Saerom", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "930834", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "A negative probability table problem of heating number in FENDL-3.1d ACE file", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A negative probability table problem of heating number in FENDL-3.1d ACE file"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/80878", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-11-04"}, "publish_date": "2020-11-04", "publish_status": "0", "recid": "80878", "relation": {}, "relation_version_is_last": true, "title": ["A negative probability table problem of heating number in FENDL-3.1d ACE file"], "weko_shared_id": -1}
A negative probability table problem of heating number in FENDL-3.1d ACE file
https://repo.qst.go.jp/records/80878
https://repo.qst.go.jp/records/80878027c0869-cb28-42d2-9d57-2d41ae8f8f2e
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-11-04 | |||||
タイトル | ||||||
タイトル | A negative probability table problem of heating number in FENDL-3.1d ACE file | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Konno, Chikara
× Konno, Chikara× Kwon, Saerom× Kwon, Saerom |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We found out that probability table (p-table) data for heating number in the FENDL-3.1d ACE files for 33 nuclei included negative values. Thus we investigated its reason in detail. As a result, it was specified that the reason was that partial KERMA factors of the radiative capture reaction became too large, because the energy-balance was broken or NJOY did not treat secondary gammas of a special format. We proposed two solutions for this issue; 1) to modify NJOY so as to calculate partial KERMA factors with the kinematics method, 2) to set p-tables for heating number to “1.0” or average heating numbers. New ACE files of FENDL-3.1d produced with the two solutions had no negative p-tables for heating number. | |||||
書誌情報 |
Proceedings of SNA+MC2020 p. 320-325, 発行日 2020-11 |