WEKO3
アイテム
{"_buckets": {"deposit": "0caf1174-f499-48c4-9bf1-a8c1241df01e"}, "_deposit": {"created_by": 1, "id": "80402", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "80402"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00080402", "sets": ["11"]}, "author_link": ["884218", "884217"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-04", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "23", "bibliographicPageStart": "18", "bibliographicVolumeNumber": "19", "bibliographic_titles": [{"bibliographic_title": "保全学"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "放射光白色X線を利用した応力評価手法および測定例を紹介する。従来のエネルギー分散を利用した手法の他に、EXDM法や、新たに開発された検出器を利用した新規ひずみ測定評価技術について述べる。", "subitem_description_type": "Abstract"}]}, "item_10004_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本保全学会"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "城, 鮎美"}], "nameIdentifiers": [{"nameIdentifier": "884217", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shiro, Ayumi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "884218", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "放射光の応用2 白色X線を利用した応力評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "放射光の応用2 白色X線を利用した応力評価"}]}, "item_type_id": "10004", "owner": "1", "path": ["11"], "permalink_uri": "https://repo.qst.go.jp/records/80402", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-04-14"}, "publish_date": "2020-04-14", "publish_status": "0", "recid": "80402", "relation": {}, "relation_version_is_last": true, "title": ["放射光の応用2 白色X線を利用した応力評価"], "weko_shared_id": -1}
放射光の応用2 白色X線を利用した応力評価
https://repo.qst.go.jp/records/80402
https://repo.qst.go.jp/records/8040270c1c444-5b38-4f8d-aa47-6c55052d5a69
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-04-14 | |||||
タイトル | ||||||
タイトル | 放射光の応用2 白色X線を利用した応力評価 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
城, 鮎美
× 城, 鮎美× Shiro, Ayumi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 放射光白色X線を利用した応力評価手法および測定例を紹介する。従来のエネルギー分散を利用した手法の他に、EXDM法や、新たに開発された検出器を利用した新規ひずみ測定評価技術について述べる。 | |||||
書誌情報 |
保全学 巻 19, 号 1, p. 18-23, 発行日 2020-04 |
|||||
出版者 | ||||||
出版者 | 日本保全学会 |