ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

Development of single-shot frequency-resolved optical gating for characterizing the instantaneous intensity and phase of LFEX laser pulses

https://repo.qst.go.jp/records/80258
https://repo.qst.go.jp/records/80258
357a50c7-5e44-4288-93eb-1802a98f2bce
Item type 会議発表論文 / Conference Paper(1)
公開日 2020-07-31
タイトル
タイトル Development of single-shot frequency-resolved optical gating for characterizing the instantaneous intensity and phase of LFEX laser pulses
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kojima, Sadaoki

× Kojima, Sadaoki

WEKO 898418

Kojima, Sadaoki

Search repository
Kojima, Sadaoki

× Kojima, Sadaoki

WEKO 898419

en Kojima, Sadaoki

Search repository
抄録
内容記述タイプ Abstract
内容記述 Frequency-resolved optical gating (FROG) is a novel means of measuring the fast motion of a critical density surface during relativistic laser–plasma interaction. Herein, we present a design and demonstration results for a new single-shot FROG system and optical transport system for characterizing the instantaneous intensity and phase at the LFEX (Laser for Fast Ignition Experiment) laser facility at the Institute of Laser Engineering of Osaka University. At LFEX, the laser intensity at the vacuum window is intrinsically high because of two unique properties, namely, the large F-number of the off-axis parabolic mirror and the small radius of the interaction chamber. Consequently, to obtain an accurate FROG trace, attention must be paid to spectrum modulation due to self-phase modulation. The appropriate laser intensity for FROG operation was investigated experimentally, and an optical transport system with an energy attenuator composed of reflective optics was designed to eliminate the concern of spectrum modulation from measurements. A FROG trace recorded at LFEX shot with 161 J energy was reconstructed 100 times using an iterative phase-retrieval algorithm. Despite some differences in structure, the reconstructed spectrum agrees reasonably well with the spectrum obtained by a time-integrated spectrometer. This shows that the developed FROG system and the optical transport system can measure the instantaneous intensity and phase of a laser pulse without spectrum modulation.
書誌情報 High Energy Density Physics

巻 37, 号 100855, 発行日 2020-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 1574-1818
DOI
識別子タイプ DOI
関連識別子 10.1016/j.hedp.2020.100855
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/abs/pii/S157418182030094X
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:58:24.770169
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3