WEKO3
アイテム
{"_buckets": {"deposit": "b4ee7576-f92a-49f3-8fe3-c7f1e559f16a"}, "_deposit": {"created_by": 1, "id": "78903", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "78903"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00078903", "sets": ["1"]}, "author_link": ["997061", "997063", "997056", "997055", "997059", "997054", "997060", "997058", "997057", "997062"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": " 023309-5", "bibliographicPageStart": " 023309-1", "bibliographicVolumeNumber": "91", "bibliographic_titles": [{"bibliographic_title": "Review of Scientific Instruments"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The National Institute of Radiological Sciences has investigated multiple-ion therapy using energetic beams of helium, carbon, oxygen, and neon ions, to improve treatment outcomes of refractory cancer. For this therapy, it is necessary to ensure the helium-ion beam purity to avoid irradiation by unwanted ions. Here, we develop a measurement method for monitoring beam purity. This method can measure the charge number of the ions in a high-purity beam using an ionization chamber and Faraday cup. In addition, it can be used to detect the contamination of the clinical helium-ion beam. We perform beam experiments to evaluate our beam-purity monitoring method and predict that our method is capable of detecting contamination below 1%.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "AIP Publishing"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1063/1.5127537", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://aip.scitation.org/doi/full/10.1063/1.5127537", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0034-6748", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mizushima, Kota"}], "nameIdentifiers": [{"nameIdentifier": "997054", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iwata, Yoshiyuki"}], "nameIdentifiers": [{"nameIdentifier": "997055", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Muramatsu, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "997056", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sung-Hyun, Lee"}], "nameIdentifiers": [{"nameIdentifier": "997057", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shirai, Toshiyuki"}], "nameIdentifiers": [{"nameIdentifier": "997058", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kota, Mizushima", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "997059", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshiyuki, Iwata", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "997060", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Masayuki, Muramatsu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "997061", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sung-Hyun, Lee", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "997062", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Toshiyuki, Shirai", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "997063", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Experimental study on monitoring system of clinical beam purity in multiple-ion beam operation for heavy-ion radiotherapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Experimental study on monitoring system of clinical beam purity in multiple-ion beam operation for heavy-ion radiotherapy"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/78903", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-02-05"}, "publish_date": "2020-02-05", "publish_status": "0", "recid": "78903", "relation": {}, "relation_version_is_last": true, "title": ["Experimental study on monitoring system of clinical beam purity in multiple-ion beam operation for heavy-ion radiotherapy"], "weko_shared_id": -1}
Experimental study on monitoring system of clinical beam purity in multiple-ion beam operation for heavy-ion radiotherapy
https://repo.qst.go.jp/records/78903
https://repo.qst.go.jp/records/78903e2da49e2-5bb3-449d-884f-4aac39d25f5f
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-02-05 | |||||
タイトル | ||||||
タイトル | Experimental study on monitoring system of clinical beam purity in multiple-ion beam operation for heavy-ion radiotherapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mizushima, Kota
× Mizushima, Kota× Iwata, Yoshiyuki× Muramatsu, Masayuki× Sung-Hyun, Lee× Shirai, Toshiyuki× Kota, Mizushima× Yoshiyuki, Iwata× Masayuki, Muramatsu× Sung-Hyun, Lee× Toshiyuki, Shirai |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The National Institute of Radiological Sciences has investigated multiple-ion therapy using energetic beams of helium, carbon, oxygen, and neon ions, to improve treatment outcomes of refractory cancer. For this therapy, it is necessary to ensure the helium-ion beam purity to avoid irradiation by unwanted ions. Here, we develop a measurement method for monitoring beam purity. This method can measure the charge number of the ions in a high-purity beam using an ionization chamber and Faraday cup. In addition, it can be used to detect the contamination of the clinical helium-ion beam. We perform beam experiments to evaluate our beam-purity monitoring method and predict that our method is capable of detecting contamination below 1%. | |||||
書誌情報 |
Review of Scientific Instruments 巻 91, 号 2, p. 023309-1-023309-5, 発行日 2020-02 |
|||||
出版者 | ||||||
出版者 | AIP Publishing | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0034-6748 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1063/1.5127537 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://aip.scitation.org/doi/full/10.1063/1.5127537 |