{"_buckets": {"deposit": "f0bfa873-6216-46e4-b740-e5c53cdae55a"}, "_deposit": {"created_by": 1, "id": "78419", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "78419"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00078419", "sets": ["1"]}, "author_link": ["1001247", "1001260", "1001255", "1001251", "1001248", "1001257", "1001249", "1001250", "1001253", "1001258", "1001259", "1001254", "1001252", "1001256"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-01", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "C01011", "bibliographicVolumeNumber": "15", "bibliographic_titles": [{"bibliographic_title": "Journal of Instrumentation"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "JT-60SA will complement ITER in resolving key issues to finally decide an acceptable DEMO design. Diagnostics play a key role in this mission. The electron temperature and density profiles are measured by a core and an edge Thomson scattering (TS) diagnostics with high spatial resolution, needed to identify the pedestal parameters and small profile structures. The two systems use a common tangential Nd:YAG laser beam path in the plasma equatorial plane. The collection optics for the edge system (low field side) is hosted in a lower oblique port and that for the core system in a horizontal port. The optics fit in the port plug tube and image the scattering volumes into an array of fiber bundles. They both are exposed to a high neutron dose of 10^16 n/cm^2 over 13 years of operation. The optics are supported by a mechanical structure decoupled from the cryostat. A set of filter polychromators with avalanche photodiode (APD) detectors spectrally analyze the scattered radiation. The development of the TS systems is carried out by a joint Japan-EU team. The conceptual design of the edge TS system is presented here. Simulations of the TS signals show acceptable accuracy down to 1 × 10^19 m^−3 electron density, sufficient to measure the edge gradient and even a small region outside the separatrix.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IOP Publishing "}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1088/1748-0221/15/01/C01011", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1088/1748-0221/15/01/C01011", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1748-0221", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Pasqualotto, Roberto"}], "nameIdentifiers": [{"nameIdentifier": "1001247", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tojo, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "1001248", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fassina, Alessandro"}], "nameIdentifiers": [{"nameIdentifier": "1001249", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Giudicotti, Leonardo"}], "nameIdentifiers": [{"nameIdentifier": "1001250", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nardino, Vanni"}], "nameIdentifiers": [{"nameIdentifier": "1001251", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Oyama, Naoyuki"}], "nameIdentifiers": [{"nameIdentifier": "1001252", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Pelli, Stefano"}], "nameIdentifiers": [{"nameIdentifier": "1001253", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Raimondi, Valentina"}], "nameIdentifiers": [{"nameIdentifier": "1001254", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ricciarini, Sergio"}], "nameIdentifiers": [{"nameIdentifier": "1001255", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Soare, Sorin"}], "nameIdentifiers": [{"nameIdentifier": "1001256", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Davis, Sam"}], "nameIdentifiers": [{"nameIdentifier": "1001257", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sozzi, Carlo"}], "nameIdentifiers": [{"nameIdentifier": "1001258", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hiroshi, Tojo", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1001259", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Naoyuki, Oyama", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1001260", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Conceptual design of JT-60SA edge Thomson scattering diagnostic", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Conceptual design of JT-60SA edge Thomson scattering diagnostic"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/78419", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-01-14"}, "publish_date": "2020-01-14", "publish_status": "0", "recid": "78419", "relation": {}, "relation_version_is_last": true, "title": ["Conceptual design of JT-60SA edge Thomson scattering diagnostic"], "weko_shared_id": -1}
Conceptual design of JT-60SA edge Thomson scattering diagnostic
https://repo.qst.go.jp/records/78419
https://repo.qst.go.jp/records/784193e3fb439-2e51-4bed-9c7f-f19223337e3b
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-01-14 | |||||
タイトル | ||||||
タイトル | Conceptual design of JT-60SA edge Thomson scattering diagnostic | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Pasqualotto, Roberto
× Pasqualotto, Roberto× Tojo, Hiroshi× Fassina, Alessandro× Giudicotti, Leonardo× Nardino, Vanni× Oyama, Naoyuki× Pelli, Stefano× Raimondi, Valentina× Ricciarini, Sergio× Soare, Sorin× Davis, Sam× Sozzi, Carlo× Hiroshi, Tojo× Naoyuki, Oyama |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | JT-60SA will complement ITER in resolving key issues to finally decide an acceptable DEMO design. Diagnostics play a key role in this mission. The electron temperature and density profiles are measured by a core and an edge Thomson scattering (TS) diagnostics with high spatial resolution, needed to identify the pedestal parameters and small profile structures. The two systems use a common tangential Nd:YAG laser beam path in the plasma equatorial plane. The collection optics for the edge system (low field side) is hosted in a lower oblique port and that for the core system in a horizontal port. The optics fit in the port plug tube and image the scattering volumes into an array of fiber bundles. They both are exposed to a high neutron dose of 10^16 n/cm^2 over 13 years of operation. The optics are supported by a mechanical structure decoupled from the cryostat. A set of filter polychromators with avalanche photodiode (APD) detectors spectrally analyze the scattered radiation. The development of the TS systems is carried out by a joint Japan-EU team. The conceptual design of the edge TS system is presented here. Simulations of the TS signals show acceptable accuracy down to 1 × 10^19 m^−3 electron density, sufficient to measure the edge gradient and even a small region outside the separatrix. | |||||
書誌情報 |
Journal of Instrumentation 巻 15, p. C01011, 発行日 2020-01 |
|||||
出版者 | ||||||
出版者 | IOP Publishing | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1748-0221 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1088/1748-0221/15/01/C01011 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1088/1748-0221/15/01/C01011 |