{"_buckets": {"deposit": "1dea5aff-6f15-4d98-a33b-1d40b234f8ed"}, "_deposit": {"created_by": 1, "id": "77145", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "77145"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00077145", "sets": ["29"]}, "author_link": ["793862", "793859", "793861", "793858", "793856", "793860", "793863", "793857", "793855"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2019-10-30", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A small animal depth-of-interaction (DOI) positron emission tomography (PET) detector based on a trapezoid shaped crystal was originally proposed by Simon Cherry’s group at UC Davis as a way to minimize the gaps between detector blocks. However, manufacturing the trapezoid shaped crystal is costly due to the complex geometry. As a more practical idea, here we developed a small animal DOI PET detector using a sub-surface laser engraving (SSLE) based trapezoid geometry. The imaging performance of the proposed PET scanner was presented in the most recent GATE User’s workshop. In the developed detector, we pixelized a 20 mm long monolithic trapezoid LYSO plate (top = 15.3 mm, bottom = 25.6 mm, thickness = 0.9 mm) into a 15 × 1 array by using SSLE to yield a top crystal pitch of 1.02 mm and a bottom crystal pitch of 1.71 mm. The 11 SSLE processed LYSO crystal plates were assembled together to make a 15 × 11 array. The LYSO plates were optically isolated by using as enhanced specular reflector (ESR). A 7×6 array SiPM (S13360-2050VE, Hamamatsu Photonics, Japan) with a pixel pitch of 2.4 mm and an 8×4 array SiPM (S13361-3050NE-04 Hamamatsu Photonics) with a pixel pitch of 3.2 mm were coupled to the top and bottom surfaces of the trapezoid LYSO array, respectively. For an optical coupling, room temperature vulcanized (RTV) light guides with a thickness of 1 mm were inserted between the LYSO and SiPM array. The SiPM output signals were multiplexed by using a resistive network, and then digitized by CAMAC DAQ. We could identify all the crystals in the 2D flood map. The measured DOI resolution and energy resolution were 2.3±0.6 mm and 11.6±0.7%, respectively. In the future, we want to develop a prototype trapezoid geometry small animal DOI PET scanner for high-resolution and high-sensitivity mouse brain imaging.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "2019 IEEE Nuclear Science Symposium and Medical Imaging Conference", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kang, Hangyu"}], "nameIdentifiers": [{"nameIdentifier": "793855", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishikido, Fumihiko"}], "nameIdentifiers": [{"nameIdentifier": "793856", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashima, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "793857", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakai, Toshiaki"}], "nameIdentifiers": [{"nameIdentifier": "793858", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "793859", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kang, Hangyu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "793860", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishikido, Fumihiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "793861", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashima, Hideaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "793862", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "793863", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Initial Results for a Small Animal DOI PET Detector with Sub-Surface Laser Engraving Based Trapezoid Geometry", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Initial Results for a Small Animal DOI PET Detector with Sub-Surface Laser Engraving Based Trapezoid Geometry"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/77145", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-10-16"}, "publish_date": "2019-10-16", "publish_status": "0", "recid": "77145", "relation": {}, "relation_version_is_last": true, "title": ["Initial Results for a Small Animal DOI PET Detector with Sub-Surface Laser Engraving Based Trapezoid Geometry"], "weko_shared_id": -1}
Initial Results for a Small Animal DOI PET Detector with Sub-Surface Laser Engraving Based Trapezoid Geometry
https://repo.qst.go.jp/records/77145
https://repo.qst.go.jp/records/77145ab295be5-bafa-4b69-9660-0fdb62a096b9
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-10-16 | |||||
タイトル | ||||||
タイトル | Initial Results for a Small Animal DOI PET Detector with Sub-Surface Laser Engraving Based Trapezoid Geometry | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kang, Hangyu
× Kang, Hangyu× Nishikido, Fumihiko× Tashima, Hideaki× Sakai, Toshiaki× Yamaya, Taiga× Kang, Hangyu× Nishikido, Fumihiko× Tashima, Hideaki× Yamaya, Taiga |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A small animal depth-of-interaction (DOI) positron emission tomography (PET) detector based on a trapezoid shaped crystal was originally proposed by Simon Cherry’s group at UC Davis as a way to minimize the gaps between detector blocks. However, manufacturing the trapezoid shaped crystal is costly due to the complex geometry. As a more practical idea, here we developed a small animal DOI PET detector using a sub-surface laser engraving (SSLE) based trapezoid geometry. The imaging performance of the proposed PET scanner was presented in the most recent GATE User’s workshop. In the developed detector, we pixelized a 20 mm long monolithic trapezoid LYSO plate (top = 15.3 mm, bottom = 25.6 mm, thickness = 0.9 mm) into a 15 × 1 array by using SSLE to yield a top crystal pitch of 1.02 mm and a bottom crystal pitch of 1.71 mm. The 11 SSLE processed LYSO crystal plates were assembled together to make a 15 × 11 array. The LYSO plates were optically isolated by using as enhanced specular reflector (ESR). A 7×6 array SiPM (S13360-2050VE, Hamamatsu Photonics, Japan) with a pixel pitch of 2.4 mm and an 8×4 array SiPM (S13361-3050NE-04 Hamamatsu Photonics) with a pixel pitch of 3.2 mm were coupled to the top and bottom surfaces of the trapezoid LYSO array, respectively. For an optical coupling, room temperature vulcanized (RTV) light guides with a thickness of 1 mm were inserted between the LYSO and SiPM array. The SiPM output signals were multiplexed by using a resistive network, and then digitized by CAMAC DAQ. We could identify all the crystals in the 2D flood map. The measured DOI resolution and energy resolution were 2.3±0.6 mm and 11.6±0.7%, respectively. In the future, we want to develop a prototype trapezoid geometry small animal DOI PET scanner for high-resolution and high-sensitivity mouse brain imaging. | |||||