WEKO3
アイテム
{"_buckets": {"deposit": "379da6a1-ecf9-4e05-84f0-655d9e39a447"}, "_deposit": {"created_by": 1, "id": "76864", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "76864"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00076864", "sets": ["28"]}, "author_link": ["785045", "785048", "785049", "785047", "785042", "785043", "785044", "785046"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2019-10-01", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Positron emission tomography (PET) has been evolved with the development of new scintillation crystals such as LYSO and GAGG. The performance of a PET scanner is mainly determined by the characteristics of a scintillation crystal. The aim of this study is to compare the PET sensitivity with various scintillation crystals. In this study, a SIEMENS small animal Inveon PET (inner diameter= 161 mm, axial length= 127 mm) was modeled by using GATE Monte Carlo software (Fig.1). The Inveon PET scanner consists of 4 rings each of which has 16 detectors/ring. The PET detector block consists of 20×20 crystal array each of which has a dimension of 1.5×1.5×10 mm3. An F-18 point source with 1 MBq was placed at the center of the PET FOV and the simulation was performed for 1 s. The simulation was performed with various crystals such as BGO (Zeff=71, ρ=7.13 g/cm3), LSO (Zeff=65, ρ=7.4 g/cm3), LYSO (Zeff=61, ρ=7.20 g/cm3), GSO (Zeff=57, ρ=6.7 g/cm3), GAGG (Zeff=53, ρ=6.63 g/cm3), CsI (Zeff=54, ρ=4.51 g/cm3), and NaI (Zeff=50, ρ=3.67 g/cm3), respectively. The simulated sensitivities of BGO, LSO, LYSO, GAGG, and GSO were 12.44, 9.75, 8.61, 6.15, and 6.03%, respectively (Fig. 1(a)). The BGO resulted in a highest sensitivity and photo-fraction (Fig. 1(b)). The sensitivity of GAGG was 52% lower than that of BGO crystal. In future, the simulation results will be validated by experimental measurements.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "15th Int. SCINT 2019", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kang, Hangyu"}], "nameIdentifiers": [{"nameIdentifier": "785042", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishikido, Fumihiko"}], "nameIdentifiers": [{"nameIdentifier": "785043", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashima, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "785044", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "785045", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kang, Hangyu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "785046", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishikido, Fumihiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "785047", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashima, Hideaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "785048", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "785049", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Comparison of PET sensitivity with various scintillation crystals", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Comparison of PET sensitivity with various scintillation crystals"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/76864", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-09-19"}, "publish_date": "2019-09-19", "publish_status": "0", "recid": "76864", "relation": {}, "relation_version_is_last": true, "title": ["Comparison of PET sensitivity with various scintillation crystals"], "weko_shared_id": -1}
Comparison of PET sensitivity with various scintillation crystals
https://repo.qst.go.jp/records/76864
https://repo.qst.go.jp/records/76864424c2f6d-1df9-4fcf-a345-8fba4b173700
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-09-19 | |||||
タイトル | ||||||
タイトル | Comparison of PET sensitivity with various scintillation crystals | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kang, Hangyu
× Kang, Hangyu× Nishikido, Fumihiko× Tashima, Hideaki× Yamaya, Taiga× Kang, Hangyu× Nishikido, Fumihiko× Tashima, Hideaki× Yamaya, Taiga |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Positron emission tomography (PET) has been evolved with the development of new scintillation crystals such as LYSO and GAGG. The performance of a PET scanner is mainly determined by the characteristics of a scintillation crystal. The aim of this study is to compare the PET sensitivity with various scintillation crystals. In this study, a SIEMENS small animal Inveon PET (inner diameter= 161 mm, axial length= 127 mm) was modeled by using GATE Monte Carlo software (Fig.1). The Inveon PET scanner consists of 4 rings each of which has 16 detectors/ring. The PET detector block consists of 20×20 crystal array each of which has a dimension of 1.5×1.5×10 mm3. An F-18 point source with 1 MBq was placed at the center of the PET FOV and the simulation was performed for 1 s. The simulation was performed with various crystals such as BGO (Zeff=71, ρ=7.13 g/cm3), LSO (Zeff=65, ρ=7.4 g/cm3), LYSO (Zeff=61, ρ=7.20 g/cm3), GSO (Zeff=57, ρ=6.7 g/cm3), GAGG (Zeff=53, ρ=6.63 g/cm3), CsI (Zeff=54, ρ=4.51 g/cm3), and NaI (Zeff=50, ρ=3.67 g/cm3), respectively. The simulated sensitivities of BGO, LSO, LYSO, GAGG, and GSO were 12.44, 9.75, 8.61, 6.15, and 6.03%, respectively (Fig. 1(a)). The BGO resulted in a highest sensitivity and photo-fraction (Fig. 1(b)). The sensitivity of GAGG was 52% lower than that of BGO crystal. In future, the simulation results will be validated by experimental measurements. | |||||