Screening of uranium surface contamination on demolition debris by TXRF analysis

https://repo.qst.go.jp/records/76805
https://repo.qst.go.jp/records/76805
203229e7-a118-43f1-b9db-d18ccfddcf1e
Item type 会議発表用資料 / Presentation(1)
公開日 2019-07-05
タイトル
タイトル Screening of uranium surface contamination on demolition debris by TXRF analysis
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hiroshi.Yoshii

× Hiroshi.Yoshii

WEKO 784034

Hiroshi.Yoshii

Search repository
Izumoto, Yukie

× Izumoto, Yukie

WEKO 784035

Izumoto, Yukie

Search repository
Matsuyama, Tsygufumi

× Matsuyama, Tsygufumi

WEKO 784036

Matsuyama, Tsygufumi

Search repository
Y.Sakai

× Y.Sakai

WEKO 784037

Y.Sakai

Search repository
Yoshii, Hiroshi

× Yoshii, Hiroshi

WEKO 784038

en Yoshii, Hiroshi

Search repository
Izumoto, Yukie

× Izumoto, Yukie

WEKO 784039

en Izumoto, Yukie

Search repository
抄録
内容記述タイプ Abstract
内容記述 With the progressing decommissioning of the Fukushima Daiichi Nuclear Power Plant, the possibility that demolition debris could be contaminated with uranium will increase. Total reflection X-ray fluorescence (TXRF) analysis has been used to detect trace uranium in water [1-3]. Thus, it is likely that TXRF analysis of acid elution solution of demolition debris samples could be used to evaluate uranium surface contamination on demolition debris. In this study, we developed a methodology for screening of uranium surface contamination on demolition debris using TXRF analysis. As a model of surface shavings of contaminated demolition debris, a series of uranium solutions with different concentrations were placed on 5 g of crashed concrete/soil mixtures and dried. Subsequently, 20 mL of 4 M nitric acid solution was added to the samples and shaken for 30 min. After filtration using a hydrophilic polyvinylidene difluoride membrane (pore size of 0.1 µm), chromatography resin separation was performed. During this step, uranium was separated from the native elements of the soil and concrete including iron (present in soil and concrete in large concentrations), calcium (present in concrete in large concentrations), and rubidium whose Kα line overlaps that of the U Lα line. Bromine, with a Kβ line that also overlaps the U Lα line, remained in solution more than the other elements tested and the U Lα peak was easily separated from the Br Kβ peak by Gaussian fitting. For the TXRF measurements, 190 μL of the sample solutions were mixed with 10 μL of a 100 μg/mL gallium standard. Subsequently, 10 μL of the resulting mixture was dropped onto a fluorine resin-coated glass slide and dried for ~5 min using a heater at 80 °C. TXRF measurements were performed using a benchtop-type TXRF instrument (NANOHUNTER-II, Rigaku Corporation, Tokyo, Japan). The uranium contents of the sample solutions were higher than the spiked uranium contents due to uranium elution from the soil and concrete. This method will be useful for screening of contaminated demolition debris. This research project was conducted as regulatory supporting research funded by the Secretariat of Nuclear Regulation Authority (S/NRA/R), Japan.

[1] Matsuyama et al., J. Nucl. Sci. Technol. 54, (2017), 940.
[2] Yoshii et al., Spectrochim. Acta Part B 148, (2018) 183.
[3] Matsuyama et al., Spectrochim. Acta Part B 149, (2018), 35.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 18th International Conference on Total Reflection x-ray Fluorescence Analysis and Related Methods (TXRF2019)
発表年月日
日付 2019-06-27
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:44:42.724406
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3