{"_buckets": {"deposit": "c8de3b6e-af13-42e7-b20b-89f9e63600e6"}, "_deposit": {"created_by": 1, "id": "76800", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "76800"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00076800", "sets": ["1"]}, "author_link": ["997538", "997542", "997541", "997540", "997543", "997544", "997539"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "374", "bibliographicPageStart": "366", "bibliographicVolumeNumber": "48", "bibliographic_titles": [{"bibliographic_title": "X-ray spectrometry"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A new method based on dispersive microsolid phase extraction using graphene oxide (GO) as a solid adsorbent and total reflection X‐ray fluorescence (TXRF) spectrometry is proposed for trace determination of uranium. In the developed methodology, a suspension of GO was injected into uranium‐spiked multielement solutions including rubidium; after filtration, the membrane filter with collected GO was placed in a small volume of internal standard acid solution and the eluent containing uranium was deposited onto a fluorine resin‐ coated slide glass, which is a disposable sample stage. Using GO was effective for removal of rubidium from the measurement solution to avoid interference between Rb Kα peak and U Lα peak. The high enrichment factor of 150 enables obtaining uranium detection limits of 0.042, 0.087, and 0.12 μg L−1 for ionic strength of 0.01, 0.1, and 1 mol L−1, respectively. Such low detection limits were obtained by using a benchtop TXRF spectrometer with 5‐min measurement. The proposed method is suitable for trace uranium determination in water, including high salinity samples.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Wiley"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1002/xrs.3032", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://onlinelibrary.wiley.com/doi/abs/10.1002/xrs.3032", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0049-8246", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Takahashi, Hiroaki"}], "nameIdentifiers": [{"nameIdentifier": "997538", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Izumoto, Yukie"}], "nameIdentifiers": [{"nameIdentifier": "997539", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuyama, Tsugufumi"}], "nameIdentifiers": [{"nameIdentifier": "997540", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshii, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "997541", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yukie, Izumoto", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "997542", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsugufumi, Matsuyama", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "997543", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hiroshi, Yoshii", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "997544", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Trace determination of uranium preconcentrated using graphene oxide by total reflection X‐ray fluorescence spectrometry", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Trace determination of uranium preconcentrated using graphene oxide by total reflection X‐ray fluorescence spectrometry"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/76800", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-09-17"}, "publish_date": "2019-09-17", "publish_status": "0", "recid": "76800", "relation": {}, "relation_version_is_last": true, "title": ["Trace determination of uranium preconcentrated using graphene oxide by total reflection X‐ray fluorescence spectrometry"], "weko_shared_id": -1}
Trace determination of uranium preconcentrated using graphene oxide by total reflection X‐ray fluorescence spectrometry
https://repo.qst.go.jp/records/76800
https://repo.qst.go.jp/records/76800eb178015-98ba-4f2a-87a7-72adbd87c5ba
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-09-17 | |||||
タイトル | ||||||
タイトル | Trace determination of uranium preconcentrated using graphene oxide by total reflection X‐ray fluorescence spectrometry | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Takahashi, Hiroaki
× Takahashi, Hiroaki× Izumoto, Yukie× Matsuyama, Tsugufumi× Yoshii, Hiroshi× Yukie, Izumoto× Tsugufumi, Matsuyama× Hiroshi, Yoshii |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A new method based on dispersive microsolid phase extraction using graphene oxide (GO) as a solid adsorbent and total reflection X‐ray fluorescence (TXRF) spectrometry is proposed for trace determination of uranium. In the developed methodology, a suspension of GO was injected into uranium‐spiked multielement solutions including rubidium; after filtration, the membrane filter with collected GO was placed in a small volume of internal standard acid solution and the eluent containing uranium was deposited onto a fluorine resin‐ coated slide glass, which is a disposable sample stage. Using GO was effective for removal of rubidium from the measurement solution to avoid interference between Rb Kα peak and U Lα peak. The high enrichment factor of 150 enables obtaining uranium detection limits of 0.042, 0.087, and 0.12 μg L−1 for ionic strength of 0.01, 0.1, and 1 mol L−1, respectively. Such low detection limits were obtained by using a benchtop TXRF spectrometer with 5‐min measurement. The proposed method is suitable for trace uranium determination in water, including high salinity samples. | |||||
書誌情報 |
X-ray spectrometry 巻 48, 号 5, p. 366-374, 発行日 2019-09 |
|||||
出版者 | ||||||
出版者 | Wiley | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0049-8246 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1002/xrs.3032 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://onlinelibrary.wiley.com/doi/abs/10.1002/xrs.3032 |