WEKO3
アイテム
Radiolabeling and evaluation of isoDGR derivative using radioactive cooper
https://repo.qst.go.jp/records/76664
https://repo.qst.go.jp/records/766649effe2d3-a054-4959-8a18-777fc07ab40e
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-09-05 | |||||
タイトル | ||||||
タイトル | Radiolabeling and evaluation of isoDGR derivative using radioactive cooper | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hanyu, Masayuki
× Hanyu, Masayuki× Xie, Lin× Kuan, Hu× Yang, Zhimin× Zhang, Yiding× Suzuki, Hisashi× Ming-Rong, Zhang× Hanyu, Masayuki× Xie, Lin× Kuan, Hu× Yang, Zhimin× Zhang, Yiding× Suzuki, Hisashi× Ming-Rong, Zhang |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Integrins play a pivotal role in many physiological processes such as neo-angiogenesis, cell adhesion and proliferation, and thus are key proteins in pathological disorders such as cancer metastasis, thrombosis, osteoporosis, and autoimmune diseases. For molecular imaging agents based on small peptidic integrin ligands, such as the αvβ3-integrin ligand c(RGDfK), has been found to greatly improve target affinities and in vivo performance. Kessler et al. described the systematic screening of c(-phgisoDGR-X-) lead motif aiming to confer to the small lead pentapeptide selectivity toward the Fn-binding integrins α5β1 and αvβ6 (1). The cyclic peptide c(-phg-isoDGR-k-) displayed an antagonistic activity for α5β1 (IC50: 8.7 nM), thus representing the first report of a small-sized, highly active, cyclic peptide selectively targeting α5β1 integrins (2). Cu-64 labeled ligands are useful in PET studies because of the clinically suitable nuclear properties of Cu-64 and its availability at high molar activity. This property allows sufficient time for clearance of non-specific radioactivity from background tissues to increase image contrast, which requires long times to circulate throughout the whole body. Moreover, Cu-64 labeled ligands are demonstrably effective for radioimmunotherapy. Meanwhile, Cu-67 is one of the most promising radioactive metals for radiotherapy. Here, we report radiolabeling and evaluation of c(-phg-isoDGR-k(DOTA)-) using radioactive cooper. (1) Frank, A. O. et al. Angew. Chem., Int. Ed. 2010, 49, 9278−9281. (2) Bochen, A. et al. J. Med. Chem. 2013, 56, 1509−1519. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 14th International Comference on Radiopharmaceutical Therapy | |||||
発表年月日 | ||||||
日付 | 2019-08-23 | |||||
日付タイプ | Issued |