WEKO3
アイテム
{"_buckets": {"deposit": "1978b039-4af7-4fea-af45-4a5317921826"}, "_deposit": {"created_by": 1, "id": "75621", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "75621"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00075621", "sets": ["29"]}, "author_link": ["744092", "744091"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2019-04-12", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "[Purpose] Carbon ion (C-ion) radiotherapy is better than the external photon radiotherapy because of C-ion’s higher concentration of dose and greater biological effects on the peripheral area of Bragg peak. The scanning method can realize the ideal shape of dose distribution for a coverage of target. It is important for passive method with a broad-beam to consider the radiation quality only along with depth for relative biological effectiveness (RBE). However, the lateral distribution of C-ion beam’s radiation quality must be considered for using scanning irradiation to confirm the uniformity of biological dose. In this study, the lateral radiation quality of C-ion beams is shown with the empirical model for biological dose estimation. \n[Method] The lateral dose, dose-averaged LET- (LETd) and RBE-distribution for of monochrome C-ion pencil beam with three incident kinetic energy (230, 290, 350 MeV/u) were derived with Monte Carlo tool Geant4.10.01.p03, respectively. The RBE as a biological index was calculated with a mixed-beam model, which is an empirical model developed by NIRS.\n[Results] The more the kinetic energy increases, the more dose distribution of primary C-ion beam spread from 10 mm to 16 mm in Bragg peak area, which looks like three-Gaussian. While the shape of RBE-distribution is similar to dose one, LETd distribution looks like a shape of well, which has a peak region at around 5 to 10 mm of radius. \n[Discussion] The C-ion has known as a high-LET particle around Bragg peak, it’s especially about beam’s depth direction. Although the lateral distribution had been not known well, the LETd distribution became obvious as a well-shape distribution in this study. The lateral radiation quality is critical for a spot scanning method because the biological dose distribution must be conformed three-dimensionally about a number of spot, which is not like broad-beam method. \n[Conclusion] We showed the lateral distributions of C-ion beams. These results may help you get the knowledge to understand the biological effects of spot scanning method.\n", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "117th Scientific Meeting of JSMP", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "中路, 拓"}], "nameIdentifiers": [{"nameIdentifier": "744091", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakaji, Taku", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "744092", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "The Monte Carlo simulation for lateral radiation quality of carbon ion beam with the empirical model", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "The Monte Carlo simulation for lateral radiation quality of carbon ion beam with the empirical model"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/75621", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-04-17"}, "publish_date": "2019-04-17", "publish_status": "0", "recid": "75621", "relation": {}, "relation_version_is_last": true, "title": ["The Monte Carlo simulation for lateral radiation quality of carbon ion beam with the empirical model"], "weko_shared_id": -1}
The Monte Carlo simulation for lateral radiation quality of carbon ion beam with the empirical model
https://repo.qst.go.jp/records/75621
https://repo.qst.go.jp/records/75621dfb3c6d9-905f-4d51-9cef-d51d620ab889
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-04-17 | |||||
タイトル | ||||||
タイトル | The Monte Carlo simulation for lateral radiation quality of carbon ion beam with the empirical model | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
中路, 拓
× 中路, 拓× Nakaji, Taku |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | [Purpose] Carbon ion (C-ion) radiotherapy is better than the external photon radiotherapy because of C-ion’s higher concentration of dose and greater biological effects on the peripheral area of Bragg peak. The scanning method can realize the ideal shape of dose distribution for a coverage of target. It is important for passive method with a broad-beam to consider the radiation quality only along with depth for relative biological effectiveness (RBE). However, the lateral distribution of C-ion beam’s radiation quality must be considered for using scanning irradiation to confirm the uniformity of biological dose. In this study, the lateral radiation quality of C-ion beams is shown with the empirical model for biological dose estimation. [Method] The lateral dose, dose-averaged LET- (LETd) and RBE-distribution for of monochrome C-ion pencil beam with three incident kinetic energy (230, 290, 350 MeV/u) were derived with Monte Carlo tool Geant4.10.01.p03, respectively. The RBE as a biological index was calculated with a mixed-beam model, which is an empirical model developed by NIRS. [Results] The more the kinetic energy increases, the more dose distribution of primary C-ion beam spread from 10 mm to 16 mm in Bragg peak area, which looks like three-Gaussian. While the shape of RBE-distribution is similar to dose one, LETd distribution looks like a shape of well, which has a peak region at around 5 to 10 mm of radius. [Discussion] The C-ion has known as a high-LET particle around Bragg peak, it’s especially about beam’s depth direction. Although the lateral distribution had been not known well, the LETd distribution became obvious as a well-shape distribution in this study. The lateral radiation quality is critical for a spot scanning method because the biological dose distribution must be conformed three-dimensionally about a number of spot, which is not like broad-beam method. [Conclusion] We showed the lateral distributions of C-ion beams. These results may help you get the knowledge to understand the biological effects of spot scanning method. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 117th Scientific Meeting of JSMP | |||||
発表年月日 | ||||||
日付 | 2019-04-12 | |||||
日付タイプ | Issued |