{"_buckets": {"deposit": "7022c558-602e-4aca-af21-ff1b8644c1e2"}, "_deposit": {"created_by": 1, "id": "75531", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "75531"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00075531", "sets": ["1"]}, "author_link": ["893990", "893984", "893988", "893987", "893991", "893986", "893989", "893993", "893992", "893985"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-04", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "007", "bibliographicPageStart": "001", "bibliographicVolumeNumber": "3", "bibliographic_titles": [{"bibliographic_title": "Journal of Radiology and Oncology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: The purpose of this study was to evaluate biological dose in single-field optimization (SFO) and multi-field optimization (MFO) intensity-modulated proton therapy (IMPT) plans for brain tumor patients that used a fixed relative biological effectiveness (FRBE) and those that used a variable RBE (VRBE).\nMaterials and methods: SFO and MFO IMPT plans were planned by the Varian Eclipse treatment planning system for three brain tumor patients. Dose and linear energy transfer (LET) distributions for each plan were recomputed using an in-house fast Monte Carlo dose calculator system, and then biological dose distributions were calculated with a FRBE of 1.1 or with a previously published VRBE model. We then compared biological dose distributions obtained by the VRBE with those obtained by the FRBE.\nResults: Doses obtained by the VRBE for the gross tumor volume and clinical target volume in all plans were 1%-2% larger than those obtained by the FRBE. The minimum dose obtained by the VRBE for the brainstem in the SFO IMPT of one patient was 140% larger than that obtained by the FRBE, but the difference was only 5.3 cGy (RBE). The difference in maximum dose for the optic chiasm in the MFO IMPT of another patient was less than 3.2%, but the dose difference was 149.2 cGy (RBE). We also found that no major differences were seen between the biological dose differences in the SFO IMPT plans and those in the MFO IMPT plans.\nConclusion: We could observe biological dose differences between the FRBE and the VRBE in the SFO and the MFO IMPT plans for brain tumor patients.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Heighten Science Publications Corporation"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.29328/journal.jro.1001027", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.heighpubs.org/jro/jro-aid1027.php", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2573-7724", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "河野, 良介"}], "nameIdentifiers": [{"nameIdentifier": "893984", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kohno, Ryosuke"}], "nameIdentifiers": [{"nameIdentifier": "893985", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Cao, Wenhua"}], "nameIdentifiers": [{"nameIdentifier": "893986", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yepes, Pablo"}], "nameIdentifiers": [{"nameIdentifier": "893987", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Bai, Xuemin"}], "nameIdentifiers": [{"nameIdentifier": "893988", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Poenisch, Falk"}], "nameIdentifiers": [{"nameIdentifier": "893989", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "R Grosshans, David"}], "nameIdentifiers": [{"nameIdentifier": "893990", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akimoto, Tetsuo"}], "nameIdentifiers": [{"nameIdentifier": "893991", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mohan, Radhe"}], "nameIdentifiers": [{"nameIdentifier": "893992", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kohno, Ryosuke", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "893993", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Biological Dose Calculation using variable RBE in Single- and Multi-field Optimization IMPT plans for 3 Brain Tumor patients", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Biological Dose Calculation using variable RBE in Single- and Multi-field Optimization IMPT plans for 3 Brain Tumor patients"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/75531", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-04-02"}, "publish_date": "2019-04-02", "publish_status": "0", "recid": "75531", "relation": {}, "relation_version_is_last": true, "title": ["Biological Dose Calculation using variable RBE in Single- and Multi-field Optimization IMPT plans for 3 Brain Tumor patients"], "weko_shared_id": -1}
Biological Dose Calculation using variable RBE in Single- and Multi-field Optimization IMPT plans for 3 Brain Tumor patients
https://repo.qst.go.jp/records/75531
https://repo.qst.go.jp/records/75531fd5f4348-cff1-44fe-87cb-31af0aad3658
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-04-02 | |||||
タイトル | ||||||
タイトル | Biological Dose Calculation using variable RBE in Single- and Multi-field Optimization IMPT plans for 3 Brain Tumor patients | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
河野, 良介
× 河野, 良介× Kohno, Ryosuke× Cao, Wenhua× Yepes, Pablo× Bai, Xuemin× Poenisch, Falk× R Grosshans, David× Akimoto, Tetsuo× Mohan, Radhe× Kohno, Ryosuke |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: The purpose of this study was to evaluate biological dose in single-field optimization (SFO) and multi-field optimization (MFO) intensity-modulated proton therapy (IMPT) plans for brain tumor patients that used a fixed relative biological effectiveness (FRBE) and those that used a variable RBE (VRBE). Materials and methods: SFO and MFO IMPT plans were planned by the Varian Eclipse treatment planning system for three brain tumor patients. Dose and linear energy transfer (LET) distributions for each plan were recomputed using an in-house fast Monte Carlo dose calculator system, and then biological dose distributions were calculated with a FRBE of 1.1 or with a previously published VRBE model. We then compared biological dose distributions obtained by the VRBE with those obtained by the FRBE. Results: Doses obtained by the VRBE for the gross tumor volume and clinical target volume in all plans were 1%-2% larger than those obtained by the FRBE. The minimum dose obtained by the VRBE for the brainstem in the SFO IMPT of one patient was 140% larger than that obtained by the FRBE, but the difference was only 5.3 cGy (RBE). The difference in maximum dose for the optic chiasm in the MFO IMPT of another patient was less than 3.2%, but the dose difference was 149.2 cGy (RBE). We also found that no major differences were seen between the biological dose differences in the SFO IMPT plans and those in the MFO IMPT plans. Conclusion: We could observe biological dose differences between the FRBE and the VRBE in the SFO and the MFO IMPT plans for brain tumor patients. |
|||||
書誌情報 |
Journal of Radiology and Oncology 巻 3, p. 001-007, 発行日 2019-04 |
|||||
出版者 | ||||||
出版者 | Heighten Science Publications Corporation | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2573-7724 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.29328/journal.jro.1001027 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.heighpubs.org/jro/jro-aid1027.php |