{"_buckets": {"deposit": "b85f7992-e508-4e62-8cc0-2719b3998bfd"}, "_deposit": {"created_by": 1, "id": "72873", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "72873"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00072873", "sets": ["28"]}, "author_link": ["718046", "718048", "718049", "718045", "718047"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2018-08-27", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Structural change and degradation of electron-beam irradiated high density polyethylene was investigated by a conventional positron annihilation lifetime spectroscopy (PALS) using 22Na positron source, gel fraction measurement, and micro-FT-IR spectroscopy immediately after the irradiation and after 3 years storage in air. The pick-off annihilation intensity of ortho-positronium (o-Ps) became small by the irradiation and after the storage maybe due to the trapping of positron by radicals/carbonyl groups. On the other hand, o-Ps lifetime did not change by the irradiation and the storage. It suggests that size of nanometer-sized free-volume is not affected by the structural change such as oxidation and cross-linking. ", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "The 13th meeting of the “Ionizing Radiation and Polymers” symposium (IRaP2018)", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "T.Oka"}], "nameIdentifiers": [{"nameIdentifier": "718045", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "N.Nagasawa"}], "nameIdentifiers": [{"nameIdentifier": "718046", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Y.Kino"}], "nameIdentifiers": [{"nameIdentifier": "718047", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "T.Sekine"}], "nameIdentifiers": [{"nameIdentifier": "718048", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長澤 尚胤", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "718049", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Long-term Oxidative Degradation of Electron Beam Irradiated High Density Polyethylene Studied by Positron Annihilation Technique", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Long-term Oxidative Degradation of Electron Beam Irradiated High Density Polyethylene Studied by Positron Annihilation Technique"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/72873", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-07-23"}, "publish_date": "2018-07-23", "publish_status": "0", "recid": "72873", "relation": {}, "relation_version_is_last": true, "title": ["Long-term Oxidative Degradation of Electron Beam Irradiated High Density Polyethylene Studied by Positron Annihilation Technique"], "weko_shared_id": -1}
Long-term Oxidative Degradation of Electron Beam Irradiated High Density Polyethylene Studied by Positron Annihilation Technique
https://repo.qst.go.jp/records/72873
https://repo.qst.go.jp/records/72873574d60ee-e351-466e-9be1-4bd643dbbca4
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-07-23 | |||||
タイトル | ||||||
タイトル | Long-term Oxidative Degradation of Electron Beam Irradiated High Density Polyethylene Studied by Positron Annihilation Technique | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
T.Oka
× T.Oka× N.Nagasawa× Y.Kino× T.Sekine× 長澤 尚胤 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Structural change and degradation of electron-beam irradiated high density polyethylene was investigated by a conventional positron annihilation lifetime spectroscopy (PALS) using 22Na positron source, gel fraction measurement, and micro-FT-IR spectroscopy immediately after the irradiation and after 3 years storage in air. The pick-off annihilation intensity of ortho-positronium (o-Ps) became small by the irradiation and after the storage maybe due to the trapping of positron by radicals/carbonyl groups. On the other hand, o-Ps lifetime did not change by the irradiation and the storage. It suggests that size of nanometer-sized free-volume is not affected by the structural change such as oxidation and cross-linking. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The 13th meeting of the “Ionizing Radiation and Polymers” symposium (IRaP2018) | |||||