WEKO3
アイテム
{"_buckets": {"deposit": "a9d2c419-d2cb-481e-b268-82b099972cb2"}, "_deposit": {"created_by": 1, "id": "72538", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "72538"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00072538", "sets": ["28"]}, "author_link": ["714397", "714399", "714398"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2017-11-24", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "By applying Direct 1 Step (D1S) MCNP with the modified nuclear data library (ACE file), it is possible to calculate the shutdown dose rate in A-FNS facility with high accuracy. In order to create the ACE files for D1S MCNP, we develop the creation code. Using this code and Fusion Evaluated Nuclear Data Libraries FENDL-3.1, we newly create the ACE files for D1S MCNP for the evaluation of the shutdown dose rate in A-FNS. We conduct the benchmark calculation by using the D1S MCNP and the newly created ACE files. From the benchmark calculation results, it is confirmed that the ACE files are successfully created.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "Plasma Conference 2017 ", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "佐藤, 聡"}], "nameIdentifiers": [{"nameIdentifier": "714397", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小迫, 和明"}], "nameIdentifiers": [{"nameIdentifier": "714398", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤 聡", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "714399", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Nuclear Data Library for Shutdown Dose Rate Calculation on Advanced Fusion Neutron Source Facility", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Nuclear Data Library for Shutdown Dose Rate Calculation on Advanced Fusion Neutron Source Facility"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/72538", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-11-21"}, "publish_date": "2017-11-21", "publish_status": "0", "recid": "72538", "relation": {}, "relation_version_is_last": true, "title": ["Nuclear Data Library for Shutdown Dose Rate Calculation on Advanced Fusion Neutron Source Facility"], "weko_shared_id": -1}
Nuclear Data Library for Shutdown Dose Rate Calculation on Advanced Fusion Neutron Source Facility
https://repo.qst.go.jp/records/72538
https://repo.qst.go.jp/records/7253844adfc53-3e87-4520-bc1e-b4ecb80498ea
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-11-21 | |||||
タイトル | ||||||
タイトル | Nuclear Data Library for Shutdown Dose Rate Calculation on Advanced Fusion Neutron Source Facility | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
佐藤, 聡
× 佐藤, 聡× 小迫, 和明× 佐藤 聡 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | By applying Direct 1 Step (D1S) MCNP with the modified nuclear data library (ACE file), it is possible to calculate the shutdown dose rate in A-FNS facility with high accuracy. In order to create the ACE files for D1S MCNP, we develop the creation code. Using this code and Fusion Evaluated Nuclear Data Libraries FENDL-3.1, we newly create the ACE files for D1S MCNP for the evaluation of the shutdown dose rate in A-FNS. We conduct the benchmark calculation by using the D1S MCNP and the newly created ACE files. From the benchmark calculation results, it is confirmed that the ACE files are successfully created. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Plasma Conference 2017 | |||||
発表年月日 | ||||||
日付 | 2017-11-24 | |||||
日付タイプ | Issued |