{"_buckets": {"deposit": "42a11b49-6f97-429e-996a-81022ec07fde"}, "_deposit": {"created_by": 1, "id": "72238", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "72238"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00072238", "sets": ["28"]}, "author_link": ["711430", "711435", "711436", "711431", "711429", "711432", "711433", "711434"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2016-09-26", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "To allow tumor targeting in the context of liver treatment planning, it is important to estimate the tumor position dynamically. In fluoroscopy, a multiple template-based method has been proposed for tumor tracking without fiducial markers. This method requires ground-truth tumor positions on training images to estimate tumor templates; however, these positions have to be manually set. Moreover, the low contrast of fluoroscopy images makes tumor position marking difficult. To solve this problem, we propose a semiautomatic tumor position tracking method for the training images to reduce both the positional error arising from the manual setup as well as the time required by setting the ground-truth manually.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "American Society for Radiation Oncology", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "平井, 隆介"}], "nameIdentifiers": [{"nameIdentifier": "711429", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂田, 幸辰"}], "nameIdentifiers": [{"nameIdentifier": "711430", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田口, 安則"}], "nameIdentifiers": [{"nameIdentifier": "711431", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森, 慎一郎"}], "nameIdentifiers": [{"nameIdentifier": "711432", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平井 隆介", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "711433", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂田 幸辰", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "711434", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田口 安則", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "711435", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "711436", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Regression Model of Tumor and Diaphragm Position for Marker-Less Tumor Tracking in Carbon Ion Scanning Therapy for Hepatocellular Carcinoma", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Regression Model of Tumor and Diaphragm Position for Marker-Less Tumor Tracking in Carbon Ion Scanning Therapy for Hepatocellular Carcinoma"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/72238", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-03-25"}, "publish_date": "2017-03-25", "publish_status": "0", "recid": "72238", "relation": {}, "relation_version_is_last": true, "title": ["Regression Model of Tumor and Diaphragm Position for Marker-Less Tumor Tracking in Carbon Ion Scanning Therapy for Hepatocellular Carcinoma"], "weko_shared_id": -1}
Regression Model of Tumor and Diaphragm Position for Marker-Less Tumor Tracking in Carbon Ion Scanning Therapy for Hepatocellular Carcinoma
https://repo.qst.go.jp/records/72238
https://repo.qst.go.jp/records/722383c2be171-7521-4b5f-a6a7-b56a9461e6c3
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-03-25 | |||||
タイトル | ||||||
タイトル | Regression Model of Tumor and Diaphragm Position for Marker-Less Tumor Tracking in Carbon Ion Scanning Therapy for Hepatocellular Carcinoma | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
平井, 隆介
× 平井, 隆介× 坂田, 幸辰× 田口, 安則× 森, 慎一郎× 平井 隆介× 坂田 幸辰× 田口 安則× 森 慎一郎 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | To allow tumor targeting in the context of liver treatment planning, it is important to estimate the tumor position dynamically. In fluoroscopy, a multiple template-based method has been proposed for tumor tracking without fiducial markers. This method requires ground-truth tumor positions on training images to estimate tumor templates; however, these positions have to be manually set. Moreover, the low contrast of fluoroscopy images makes tumor position marking difficult. To solve this problem, we propose a semiautomatic tumor position tracking method for the training images to reduce both the positional error arising from the manual setup as well as the time required by setting the ground-truth manually. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | American Society for Radiation Oncology | |||||
発表年月日 | ||||||
日付 | 2016-09-26 | |||||
日付タイプ | Issued |