Radioluminescence and Optically Stimulated luminescence studies of AI2O3:C in hadron beams.

https://repo.qst.go.jp/records/71648
https://repo.qst.go.jp/records/71648
592426f3-ac70-47de-aabc-80403054fe29
Item type 会議発表用資料 / Presentation(1)
公開日 2015-05-08
タイトル
タイトル Radioluminescence and Optically Stimulated luminescence studies of AI2O3:C in hadron beams.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nascimento, Luana

× Nascimento, Luana

WEKO 704966

Nascimento, Luana

Search repository
Vanhavere, Filip

× Vanhavere, Filip

WEKO 704967

Vanhavere, Filip

Search repository
Kodaira, Satoshi

× Kodaira, Satoshi

WEKO 704968

Kodaira, Satoshi

Search repository
Kitamura, Hisashi

× Kitamura, Hisashi

WEKO 704969

Kitamura, Hisashi

Search repository
Vangavere Filip

× Vangavere Filip

WEKO 704970

en Vangavere Filip

Search repository
小平 聡

× 小平 聡

WEKO 704971

en 小平 聡

Search repository
北村 尚

× 北村 尚

WEKO 704972

en 北村 尚

Search repository
抄録
内容記述タイプ Abstract
内容記述 The capability of radioJuminescence (RL) dosimeters composed of carbon-doped aluminium oxide (Al2O3):C detectors + optical fibre has been verified
for absorbed dose-rate measurements during carbon radiotherapy. The RL signals from two separate Al2O3:C detectors (single crystal 'CG' and droplet
'Pl1)' have been systematically measured and compared along the Bragg-curve and Spread-Out Bragg-Peak of 290 MeV/n carbon beams in the water.
The absorbed dose response was assessed for the range of 0.5 to 10 Gy. For doses up to 6G y,w e observed a linear response for both types of detectors,
while for higher doses CG presented a more prominent supraliearity than Pl. The RL response for low-LET protons in the plateau region of the Bragg
curve was found to closely resemble that observed for a clinical 6MV X-ray beam,while it was found that P1 has a better agreement with the reference data from standard ionization chamber than CG. We observed a significant decrease in luminescence efficiency with LET in the Bragg peak region. The
sludy implies that the RL-signal from AI2O3:C could potentially be suitable tor medical carbon dosimetry in the plateau range even without any LET-dependent
corrcction factors. which will be a promising tool for in-vivo therapeutic carbon beam dosimetry. A portable and robust instrument has been developed
for the routine assessment of patient exposure to ionizing radiation during radiotherapy treatments. The design principles of hardware and software were
described,along with mesurementsthat illustrate the operation of the system and its capabilities, and presented during the 17th Solid State Dosimetry in
2013 [1]. This prototype uses radioluminescence (RL) and Optically Stimulated Luminescence (OSL) from AI2O3:C detectors coupled to a PMMA optical
fiber to acquire dose in medical dosimetry. In principle,the RL/OSL prototype can provide two independent dose estimates from the same in vivo
treatment: one integrated dose estimate (OSL) and one real-time dose estimate (RL), which can be compared to one another. This report presents the
preliminary results and future work.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 平成26年度HIMAC共同利用研究成果発表会
発表年月日
日付 2015-04-21
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:48:55.267016
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3