WEKO3
アイテム
{"_buckets": {"deposit": "f1907f83-3b99-4cf3-b1f2-bebc88f3efce"}, "_deposit": {"created_by": 1, "id": "71633", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "71633"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00071633", "sets": ["28"]}, "author_link": ["704800", "704795", "704805", "704801", "704794", "704802", "704797", "704798", "704796", "704799", "704804", "704807", "704806", "704803"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2015-04-21", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In preparation of manned missions to the planet Mars and the radiation protection for the international Space Stasion several slectronic dosimetry instruments are used in space. All these instruments have different abilities. This project is to characterize the differences between three of these instruments. These are the MATROSHKA/SSD (Silicon Scintillator Detector), the ExoMars/IRAS (Ionizing Radiation Sensor) and the MSL/RAD (Radiation Assessment Detector) instruments; each of these instruments has the ability to provide dosimetry data for radiation protection. Invtwo of these instruments the organic scintillator BC-430 is used as well as inorganic scintillators like GSO, BGO and LSO. This material shows a non linear quenching effect which shall be investigated and characterized with this project.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "平成26年度HIMAC共同利用研究成果発表会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Burmeister, S."}], "nameIdentifiers": [{"nameIdentifier": "704794", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tammen, J."}], "nameIdentifiers": [{"nameIdentifier": "704795", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Elftmann, R."}], "nameIdentifiers": [{"nameIdentifier": "704796", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kulkarni, S.R."}], "nameIdentifiers": [{"nameIdentifier": "704797", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Steinhager, J."}], "nameIdentifiers": [{"nameIdentifier": "704798", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Berger, T."}], "nameIdentifiers": [{"nameIdentifier": "704799", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Y.Uchihori"}], "nameIdentifiers": [{"nameIdentifier": "704800", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "H.Kitamura"}], "nameIdentifiers": [{"nameIdentifier": "704801", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "S.Kodaira"}], "nameIdentifiers": [{"nameIdentifier": "704802", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Burmeister Sonke", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "704803", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Berger Thomas", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "704804", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "内堀 幸夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "704805", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北村 尚", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "704806", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小平 聡", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "704807", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Intercomparison and Verification of Active Dosemeters for Space", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Intercomparison and Verification of Active Dosemeters for Space"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/71633", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-04-23"}, "publish_date": "2015-04-23", "publish_status": "0", "recid": "71633", "relation": {}, "relation_version_is_last": true, "title": ["Intercomparison and Verification of Active Dosemeters for Space"], "weko_shared_id": -1}
Intercomparison and Verification of Active Dosemeters for Space
https://repo.qst.go.jp/records/71633
https://repo.qst.go.jp/records/716339eed3a74-2e1e-4642-8172-3ad6d1881456
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-04-23 | |||||
タイトル | ||||||
タイトル | Intercomparison and Verification of Active Dosemeters for Space | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Burmeister, S.
× Burmeister, S.× Tammen, J.× Elftmann, R.× Kulkarni, S.R.× Steinhager, J.× Berger, T.× Y.Uchihori× H.Kitamura× S.Kodaira× Burmeister Sonke× Berger Thomas× 内堀 幸夫× 北村 尚× 小平 聡 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In preparation of manned missions to the planet Mars and the radiation protection for the international Space Stasion several slectronic dosimetry instruments are used in space. All these instruments have different abilities. This project is to characterize the differences between three of these instruments. These are the MATROSHKA/SSD (Silicon Scintillator Detector), the ExoMars/IRAS (Ionizing Radiation Sensor) and the MSL/RAD (Radiation Assessment Detector) instruments; each of these instruments has the ability to provide dosimetry data for radiation protection. Invtwo of these instruments the organic scintillator BC-430 is used as well as inorganic scintillators like GSO, BGO and LSO. This material shows a non linear quenching effect which shall be investigated and characterized with this project. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 平成26年度HIMAC共同利用研究成果発表会 | |||||
発表年月日 | ||||||
日付 | 2015-04-21 | |||||
日付タイプ | Issued |