{"_buckets": {"deposit": "e562f922-611a-4b68-a277-2ae63c3a4daa"}, "_deposit": {"created_by": 1, "id": "71025", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "71025"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00071025", "sets": ["28"]}, "author_link": ["698077", "698075", "698080", "698079", "698076", "698083", "698081", "698084", "698073", "698078", "698082", "698074"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2010-09-24", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A portable radiation instrument with a solid-state multi-scintillator probe was newly developed. The responses to energetic protons, helium ions and neutrons were examined at domestic particle accelerators such as NIRS-HIMAC and JAEA-TIARA. As results, the detector can separate well the major cosmic-ray components in the major range of primary cosmice-ray particles. Optimization of the scintillation probe structure (scintillator thickness) and coding of an easy-to-handle particle discrimination \u0026 unfolding program are now in progress.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "16th International Conference on Solid State Dosimetry", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yasuda, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "698073", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yajima, Kazuaki"}], "nameIdentifiers": [{"nameIdentifier": "698074", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takada, Masashi"}], "nameIdentifiers": [{"nameIdentifier": "698075", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakamura, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "698076", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Endo, Akira"}], "nameIdentifiers": [{"nameIdentifier": "698077", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanimura, Yoshihiko"}], "nameIdentifiers": [{"nameIdentifier": "698078", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsutsumi, Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "698079", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fukuda, Mitsuhiro"}], "nameIdentifiers": [{"nameIdentifier": "698080", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "保田 浩志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "698081", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "矢島 千秋", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "698082", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高田 真志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "698083", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村 尚司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "698084", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "A portable cosmic radiation monitor designed for use in spacecraft and aircraft", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A portable cosmic radiation monitor designed for use in spacecraft and aircraft"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/71025", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-12-19"}, "publish_date": "2012-12-19", "publish_status": "0", "recid": "71025", "relation": {}, "relation_version_is_last": true, "title": ["A portable cosmic radiation monitor designed for use in spacecraft and aircraft"], "weko_shared_id": -1}
A portable cosmic radiation monitor designed for use in spacecraft and aircraft
https://repo.qst.go.jp/records/71025
https://repo.qst.go.jp/records/7102526aa441d-7bdc-4b0d-80e3-c08d20166833
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-12-19 | |||||
タイトル | ||||||
タイトル | A portable cosmic radiation monitor designed for use in spacecraft and aircraft | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yasuda, Hiroshi
× Yasuda, Hiroshi× Yajima, Kazuaki× Takada, Masashi× Nakamura, Takashi× Endo, Akira× Tanimura, Yoshihiko× Tsutsumi, Masahiro× Fukuda, Mitsuhiro× 保田 浩志× 矢島 千秋× 高田 真志× 中村 尚司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A portable radiation instrument with a solid-state multi-scintillator probe was newly developed. The responses to energetic protons, helium ions and neutrons were examined at domestic particle accelerators such as NIRS-HIMAC and JAEA-TIARA. As results, the detector can separate well the major cosmic-ray components in the major range of primary cosmice-ray particles. Optimization of the scintillation probe structure (scintillator thickness) and coding of an easy-to-handle particle discrimination & unfolding program are now in progress. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 16th International Conference on Solid State Dosimetry | |||||
発表年月日 | ||||||
日付 | 2010-09-24 | |||||
日付タイプ | Issued |