WEKO3
アイテム
{"_buckets": {"deposit": "0cf18f91-7b4d-41d2-b7a6-a4c4fecc76db"}, "_deposit": {"created_by": 1, "id": "70987", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "70987"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00070987", "sets": ["28"]}, "author_link": ["697751", "697766", "697749", "697752", "697759", "697763", "697748", "697747", "697755", "697754", "697753", "697758", "697760", "697757", "697764", "697750", "697761", "697762", "697756", "697765"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2012-11-03", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We are developing the OpenPET which is well suited to in-beam PET in carbon ion therapy thanks to the open space. The in-beam PET can image the distribution of positron emitters during beam irradiation for in-situ dose monitoring. Therefore careful designing and testing of OpenPET detectors are important because secondary particles generated in a target degrade detector performance in the OpenPET geometry and the quantity of positron emitters produced in in-beam PET is very small. In this paper, we optimized the final design of the in-beam OpenPET detector. Some detector components were changed from our previous work for use under practical situations. We carried out in-beam tests of this new detector for carbon beam irradiation with practical intensities. The constructed OpenPET detector consists consisted of a 16x16x4 crystal array with four-layer DOI encoding capability and a PS-PMT. The scintillator material was changed from LGSO that included radio isotopes to GSOZ. In order to compensate for the lower light yield of GSOZ, we applied the PS-PMT (R10552-100-M64) with the super bialkali photocathode which realizes 30% higher quantum efficiency than the conventional bialkali type. A large current divider circuit was applied since the PMT current exceeded the dynamic range of a normal divider circuit under the targeted practical situations. Irradiation tests were done in HIMAC. The energy and intensities of the C-12 beam were 290MeV/u and 10^8 -10^9 particles per second (pps), respectively. The detector was positioned 30cm from the backside of the water phantom at an angle of 30deg. We obtained sufficient crystal identification performance around 10^8 pps, although the position histogram was degrading slightly with increasing C-12 beam intensity. The average energy resolution of 14.9% was obtained for 511keV gamma rays. We concluded that the constructed detector was able to function as the OpenPET detector for in-beam imaging.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "2012IEEE NSS\u0026MIC", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nishikido, Fumihiko"}], "nameIdentifiers": [{"nameIdentifier": "697747", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hirano, Yoshiyuki"}], "nameIdentifiers": [{"nameIdentifier": "697748", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inadama, Naoko"}], "nameIdentifiers": [{"nameIdentifier": "697749", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "697750", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashima, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "697751", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Satou, Shinji"}], "nameIdentifiers": [{"nameIdentifier": "697752", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inaniwa, Taku"}], "nameIdentifiers": [{"nameIdentifier": "697753", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murayama, Hideo"}], "nameIdentifiers": [{"nameIdentifier": "697754", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ito, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "697755", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "697756", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "錦戸 文彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "697757", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平野 祥之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "697758", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲玉 直子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "697759", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 英治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "697760", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田島 英朗", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "697761", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤 眞二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "697762", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲庭 拓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "697763", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村山 秀雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "697764", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "伊藤 浩", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "697765", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷 泰賀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "697766", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Optimization of the in-Beam OpenPET Detector for Carbon Beam Irradiation", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Optimization of the in-Beam OpenPET Detector for Carbon Beam Irradiation"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/70987", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-11-19"}, "publish_date": "2012-11-19", "publish_status": "0", "recid": "70987", "relation": {}, "relation_version_is_last": true, "title": ["Optimization of the in-Beam OpenPET Detector for Carbon Beam Irradiation"], "weko_shared_id": -1}
Optimization of the in-Beam OpenPET Detector for Carbon Beam Irradiation
https://repo.qst.go.jp/records/70987
https://repo.qst.go.jp/records/70987d429df6a-aa9a-4284-b712-398b255318e8
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-11-19 | |||||
タイトル | ||||||
タイトル | Optimization of the in-Beam OpenPET Detector for Carbon Beam Irradiation | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nishikido, Fumihiko
× Nishikido, Fumihiko× Hirano, Yoshiyuki× Inadama, Naoko× Yoshida, Eiji× Tashima, Hideaki× Satou, Shinji× Inaniwa, Taku× Murayama, Hideo× Ito, Hiroshi× Yamaya, Taiga× 錦戸 文彦× 平野 祥之× 稲玉 直子× 吉田 英治× 田島 英朗× 佐藤 眞二× 稲庭 拓× 村山 秀雄× 伊藤 浩× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We are developing the OpenPET which is well suited to in-beam PET in carbon ion therapy thanks to the open space. The in-beam PET can image the distribution of positron emitters during beam irradiation for in-situ dose monitoring. Therefore careful designing and testing of OpenPET detectors are important because secondary particles generated in a target degrade detector performance in the OpenPET geometry and the quantity of positron emitters produced in in-beam PET is very small. In this paper, we optimized the final design of the in-beam OpenPET detector. Some detector components were changed from our previous work for use under practical situations. We carried out in-beam tests of this new detector for carbon beam irradiation with practical intensities. The constructed OpenPET detector consists consisted of a 16x16x4 crystal array with four-layer DOI encoding capability and a PS-PMT. The scintillator material was changed from LGSO that included radio isotopes to GSOZ. In order to compensate for the lower light yield of GSOZ, we applied the PS-PMT (R10552-100-M64) with the super bialkali photocathode which realizes 30% higher quantum efficiency than the conventional bialkali type. A large current divider circuit was applied since the PMT current exceeded the dynamic range of a normal divider circuit under the targeted practical situations. Irradiation tests were done in HIMAC. The energy and intensities of the C-12 beam were 290MeV/u and 10^8 -10^9 particles per second (pps), respectively. The detector was positioned 30cm from the backside of the water phantom at an angle of 30deg. We obtained sufficient crystal identification performance around 10^8 pps, although the position histogram was degrading slightly with increasing C-12 beam intensity. The average energy resolution of 14.9% was obtained for 511keV gamma rays. We concluded that the constructed detector was able to function as the OpenPET detector for in-beam imaging. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 2012IEEE NSS&MIC | |||||
発表年月日 | ||||||
日付 | 2012-11-03 | |||||
日付タイプ | Issued |