{"_buckets": {"deposit": "875811a0-63eb-4a6f-9136-aa2fb377e09a"}, "_deposit": {"created_by": 1, "id": "70265", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "70265"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00070265", "sets": ["28"]}, "author_link": ["689905", "689904"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2010-09-17", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In order to realize a precise dose distribution in heavy-ion cancer therapy, a high beam stability is required for the accelerator complex. Owing to load fluctuation caused by a upper ring, which is one of the two rings in HIMAC, current dips of \u0026#8776; 5 \u0026#8211; 10 Hz are observed in the power supply for the bending/quadrupole magnet of the other lower ring. The parameters of the beam stability, such as the spill variation, the beam position, and the size, are adversely affected by the current dips. In order to suppress these current dips, we developed a new feed-forward system in the magnet power supply. We verified the performance of the feed-forward system by measuring the suppression of the current dips. We also performed beam experiments to measure the variation of the horizontal tune and the structure of the beam spill, which is slowly extracted by the resonance method. The experimental result showed that the current dips were successfully reduced to be \u0026#61508;I/I ~ 10-6 by the system. It was also confirmed that the horizontal tune and the spill structure could be stabilized by the current dip suppression.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "ECAART10", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Katagiri, Ken"}], "nameIdentifiers": [{"nameIdentifier": "689904", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "片桐 健", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "689905", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Beam stability improvement of HIMAC synchrotronu sing a feed-forward system for magnet power supplies", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Beam stability improvement of HIMAC synchrotronu sing a feed-forward system for magnet power supplies"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/70265", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-09-30"}, "publish_date": "2010-09-30", "publish_status": "0", "recid": "70265", "relation": {}, "relation_version_is_last": true, "title": ["Beam stability improvement of HIMAC synchrotronu sing a feed-forward system for magnet power supplies"], "weko_shared_id": -1}
Beam stability improvement of HIMAC synchrotronu sing a feed-forward system for magnet power supplies
https://repo.qst.go.jp/records/70265
https://repo.qst.go.jp/records/702653ed97e10-7d82-4342-ae47-a02b27caa326
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-09-30 | |||||
タイトル | ||||||
タイトル | Beam stability improvement of HIMAC synchrotronu sing a feed-forward system for magnet power supplies | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Katagiri, Ken
× Katagiri, Ken× 片桐 健 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In order to realize a precise dose distribution in heavy-ion cancer therapy, a high beam stability is required for the accelerator complex. Owing to load fluctuation caused by a upper ring, which is one of the two rings in HIMAC, current dips of ≈ 5 – 10 Hz are observed in the power supply for the bending/quadrupole magnet of the other lower ring. The parameters of the beam stability, such as the spill variation, the beam position, and the size, are adversely affected by the current dips. In order to suppress these current dips, we developed a new feed-forward system in the magnet power supply. We verified the performance of the feed-forward system by measuring the suppression of the current dips. We also performed beam experiments to measure the variation of the horizontal tune and the structure of the beam spill, which is slowly extracted by the resonance method. The experimental result showed that the current dips were successfully reduced to be I/I ~ 10-6 by the system. It was also confirmed that the horizontal tune and the spill structure could be stabilized by the current dip suppression. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | ECAART10 | |||||
発表年月日 | ||||||
日付 | 2010-09-17 | |||||
日付タイプ | Issued |