Comparison between endoscopic findings and FDG-PET/CT that shows diffuse gastric uptakes in cancer screening

https://repo.qst.go.jp/records/69910
https://repo.qst.go.jp/records/69910
0bdb9cef-0d96-40f2-9d48-75f581615d51
Item type 会議発表用資料 / Presentation(1)
公開日 2009-10-23
タイトル
タイトル Comparison between endoscopic findings and FDG-PET/CT that shows diffuse gastric uptakes in cancer screening
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tamura, Katsumi

× Tamura, Katsumi

WEKO 686430

Tamura, Katsumi

Search repository
Sakata, Ikuko

× Sakata, Ikuko

WEKO 686431

Sakata, Ikuko

Search repository
Ishida, Jiro

× Ishida, Jiro

WEKO 686432

Ishida, Jiro

Search repository
Machida, Kikuo

× Machida, Kikuo

WEKO 686433

Machida, Kikuo

Search repository
Yoshikawa, Kyosan

× Yoshikawa, Kyosan

WEKO 686434

Yoshikawa, Kyosan

Search repository
Hasebe, Mitsuhiko

× Hasebe, Mitsuhiko

WEKO 686435

Hasebe, Mitsuhiko

Search repository
Toubaru, Sachiko

× Toubaru, Sachiko

WEKO 686436

Toubaru, Sachiko

Search repository
Ohashi, Seiya

× Ohashi, Seiya

WEKO 686437

Ohashi, Seiya

Search repository
Kosuda, Shigeru

× Kosuda, Shigeru

WEKO 686438

Kosuda, Shigeru

Search repository
Abe, Yoshiyuki

× Abe, Yoshiyuki

WEKO 686439

Abe, Yoshiyuki

Search repository
田村 克巳

× 田村 克巳

WEKO 686440

en 田村 克巳

Search repository
吉川 京燦

× 吉川 京燦

WEKO 686441

en 吉川 京燦

Search repository
長谷部 充彦

× 長谷部 充彦

WEKO 686442

en 長谷部 充彦

Search repository
桃原 幸子

× 桃原 幸子

WEKO 686443

en 桃原 幸子

Search repository
大橋 靖也

× 大橋 靖也

WEKO 686444

en 大橋 靖也

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: FDG uptakes in the stomach, especially diffuse uptakes often pester nuclear medicine physicians with the interpretation as to whether <normal or not.> The purpose of this study is to investigate the necessity of endoscopy after FDG-PET/CT that shows diffuse gastric uptakes in cancer screening. Materials and methods: We studied 50 people who had a check-up for cancer using FDG-PET/CT. All people showed diffuse uptakes in the stomach. Fifteen people were female and thirty-five people were male, and mean age was 57.3pm10.1 (36 to 80). The uptakes of the stomach were higher than of the liver in 32 people, similar to the liver in 12 people, and lower than of the liver in 6 people. Thirty-two people underwent biopsy from the stomach. Pathological findings were categorized into five groups according to the following scale: Group 1: normal tissue or benign lesion without atypical cell; Group 2: benign lesion with atypical cell ; Group 3: borderline lesion; Group 4: suspicion of cancer; Group5: cancer. Results: All people had no gastric cancer. Gastritis was detected in 35 people, ulcer in 2 people, hyperplastic polyp in 2 people, metaplasia in one. Ten people had normal findings. On the value of SUV, there was no significant difference between gastritis (3.65pm0.60SD) and normal findings (3.55pm0.33SD, p=0.619). The specimens from biopsy were Group 1 in 27 people and Group 2 in 8 people. No specimens showed Group 3, Group4, and Group 5. No significant difference was found between Group 1 (3.55pm0.59SD) and Group 2 (3.68pm0.60SD). Helicobacter.pylori was detected in 17 people. No significant difference was found between H.pylori positive group (3.70pm0.46SD) and negative group (3.43pm0.71SD, p=0.198). Conclusion: Our results indicate that an additional endoscopy for detecting gastric cancer does not seem to be necessary after FDG-PET/CT that shows diffuse uptakes in the stomach.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 2009 EANM Congress
発表年月日
日付 2009-10-14
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:09:01.789672
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3