WEKO3
アイテム
{"_buckets": {"deposit": "efbbe9a6-6bb5-4b89-8e69-1dc7fba93ec1"}, "_deposit": {"created_by": 1, "id": "69467", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "69467"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00069467", "sets": ["28"]}, "author_link": ["681756", "681766", "681767", "681763", "681762", "681765", "681757", "681761", "681764", "681759", "681760", "681758"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2008-09-12", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Radiosensitivity of genitourinary (GU) tract was estimated in terms of late toxicity against therapeutic carbon-ion beam during prostate cancer therapy. NTCP analysis revealed that the alpha/beta value of the GU was 7.7, that was more than 2 times higher than that against photons (3.0) in literature. BED calculated with the alpha/beta value for carbon-ion beam was 73.8, which was consistent with that for photons, 74.7. The information will contribute in the prospective estimation of prescribed dose in different fractionation or further dose optimization in treatment planning.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "5th Korea-Japan Joint Meeting on Medical Physics", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Matsufuji, Naruhiro"}], "nameIdentifiers": [{"nameIdentifier": "681756", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsuji, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "681757", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kase, Yuuki"}], "nameIdentifiers": [{"nameIdentifier": "681758", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanai, Tatsuaki"}], "nameIdentifiers": [{"nameIdentifier": "681759", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kamada, Tadashi"}], "nameIdentifiers": [{"nameIdentifier": "681760", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsujii, Hirohiko"}], "nameIdentifiers": [{"nameIdentifier": "681761", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松藤 成弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "681762", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "辻 比呂志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "681763", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加瀬 優紀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "681764", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金井 達明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "681765", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鎌田 正", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "681766", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "辻井 博彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "681767", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Radiosensitivity of Genitourinary Tract against Therapeutic Carbon-Ion Beam of HIMAC", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Radiosensitivity of Genitourinary Tract against Therapeutic Carbon-Ion Beam of HIMAC"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/69467", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-09-25"}, "publish_date": "2008-09-25", "publish_status": "0", "recid": "69467", "relation": {}, "relation_version_is_last": true, "title": ["Radiosensitivity of Genitourinary Tract against Therapeutic Carbon-Ion Beam of HIMAC"], "weko_shared_id": -1}
Radiosensitivity of Genitourinary Tract against Therapeutic Carbon-Ion Beam of HIMAC
https://repo.qst.go.jp/records/69467
https://repo.qst.go.jp/records/694675555e08a-1685-4f2d-abcf-66b0243cf566
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-09-25 | |||||
タイトル | ||||||
タイトル | Radiosensitivity of Genitourinary Tract against Therapeutic Carbon-Ion Beam of HIMAC | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Matsufuji, Naruhiro
× Matsufuji, Naruhiro× Tsuji, Hiroshi× Kase, Yuuki× Kanai, Tatsuaki× Kamada, Tadashi× Tsujii, Hirohiko× 松藤 成弘× 辻 比呂志× 加瀬 優紀× 金井 達明× 鎌田 正× 辻井 博彦 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Radiosensitivity of genitourinary (GU) tract was estimated in terms of late toxicity against therapeutic carbon-ion beam during prostate cancer therapy. NTCP analysis revealed that the alpha/beta value of the GU was 7.7, that was more than 2 times higher than that against photons (3.0) in literature. BED calculated with the alpha/beta value for carbon-ion beam was 73.8, which was consistent with that for photons, 74.7. The information will contribute in the prospective estimation of prescribed dose in different fractionation or further dose optimization in treatment planning. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 5th Korea-Japan Joint Meeting on Medical Physics | |||||
発表年月日 | ||||||
日付 | 2008-09-12 | |||||
日付タイプ | Issued |