Experience of Transfer Work of PACS Image Data in Multivendor Environment

https://repo.qst.go.jp/records/69454
https://repo.qst.go.jp/records/69454
4f7c2d24-b471-4cc3-a2ab-be5bcee65dbe
Item type 会議発表用資料 / Presentation(1)
公開日 2008-09-17
タイトル
タイトル Experience of Transfer Work of PACS Image Data in Multivendor Environment
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mukai, Masami

× Mukai, Masami

WEKO 681612

Mukai, Masami

Search repository
Tanikawa, Takumi

× Tanikawa, Takumi

WEKO 681613

Tanikawa, Takumi

Search repository
Ando, Yutaka

× Ando, Yutaka

WEKO 681614

Ando, Yutaka

Search repository
et.al

× et.al

WEKO 681615

et.al

Search repository
向井 まさみ

× 向井 まさみ

WEKO 681616

en 向井 まさみ

Search repository
谷川 琢海

× 谷川 琢海

WEKO 681617

en 谷川 琢海

Search repository
安藤 裕

× 安藤 裕

WEKO 681618

en 安藤 裕

Search repository
抄録
内容記述タイプ Abstract
内容記述 The Heavy Particle Medical Science Center, affiliated to the National Institute of Radiological Sciences, began archiving digital medical images from 1995, and launched film-less operation from August 2005. Then, in fiscal 2006, PACS was changed into the duplex configuration to upgrade the server equipment and avoid problems. Before starting system operation, the image data managed by the old image system were transferred to the new image management system. The applicable data were approximately 12 million images obtained from approximately 130,000 cases of examination, and the categories of modality were CR, CT, DR, ES, MR, NM, PET, RF, SC, US, XA, and OT. The data transfer work was completed in approximately three months using the Q/R connection of DICOM. We repeated a procedure which extracts images UID from both the source and destination systems after the transfer has finished, compares them with each other, surveys causes if any differences are found, corrects the data appropriately, and stores the data again. The primary cause of such differences was that the management method of images including the multi-frame type (especially on a per-examination basis) was different depending on the system.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 5th KOREA-JAPAN Joint Meeting on Medical Physics
発表年月日
日付 2008-09-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:14:18.036543
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3