WEKO3
アイテム
{"_buckets": {"deposit": "d0b7ed66-5a3c-4798-89ab-5807b68062cd"}, "_deposit": {"created_by": 1, "id": "68799", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "68799"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00068799", "sets": ["28"]}, "author_link": ["675234", "675237", "675239", "675240", "675242", "675236", "675241", "675238", "675235"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2006-05-12", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Gadolinium (Gd) based dynamic susceptibility contrast (DSC) agents allow brain perfusion NMR images in both animal and human [1,2,3,4]. It is not easy to model the arterial input function (AIF) in small animals because of the small ratio of artery to tissue in a voxel. Hence, cerebral blood flow (CBF) values estimated from DSC images can be inaccurate. As an alternative, the maximum value of the logarithmic signal ratio (maxDELTA R2*) is occasionally used as an indicator of the CBF in the rat brain [3,4]. To investigate the accuracy of CBF indicated by maxDELTA R2* in the ischemic rat brain, a comparison of the CBF values obtained with continuous arterial spin labeling (CASL) and maxDELTA R2* was performed in an ischemic rat model.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "International Society for Magnetic Resonance in Medicine(ISMRM) 14th Scientific Meeting and Exhibition", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nakamura, Kazuhiro"}], "nameIdentifiers": [{"nameIdentifier": "675234", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Masanobu, Ibaraki"}], "nameIdentifiers": [{"nameIdentifier": "675235", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kershaw, Jeffrey"}], "nameIdentifiers": [{"nameIdentifier": "675236", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanno, Iwao"}], "nameIdentifiers": [{"nameIdentifier": "675237", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "675238", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村 和浩", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "675239", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "茨木 正信", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "675240", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kershaw Jeffrey", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "675241", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "菅野 巖", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "675242", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Comparison of cerebral blood flow estimates in the ischemic area of rat brain obtained with dynamic susceptibility contrast and continuous arterial spin labeling", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Comparison of cerebral blood flow estimates in the ischemic area of rat brain obtained with dynamic susceptibility contrast and continuous arterial spin labeling"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/68799", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-11-28"}, "publish_date": "2006-11-28", "publish_status": "0", "recid": "68799", "relation": {}, "relation_version_is_last": true, "title": ["Comparison of cerebral blood flow estimates in the ischemic area of rat brain obtained with dynamic susceptibility contrast and continuous arterial spin labeling"], "weko_shared_id": -1}
Comparison of cerebral blood flow estimates in the ischemic area of rat brain obtained with dynamic susceptibility contrast and continuous arterial spin labeling
https://repo.qst.go.jp/records/68799
https://repo.qst.go.jp/records/687993fb2ceff-ade0-4104-b245-0cc08d4b9b2c
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-11-28 | |||||
タイトル | ||||||
タイトル | Comparison of cerebral blood flow estimates in the ischemic area of rat brain obtained with dynamic susceptibility contrast and continuous arterial spin labeling | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nakamura, Kazuhiro
× Nakamura, Kazuhiro× Masanobu, Ibaraki× Kershaw, Jeffrey× Kanno, Iwao× et.al× 中村 和浩× 茨木 正信× Kershaw Jeffrey× 菅野 巖 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Gadolinium (Gd) based dynamic susceptibility contrast (DSC) agents allow brain perfusion NMR images in both animal and human [1,2,3,4]. It is not easy to model the arterial input function (AIF) in small animals because of the small ratio of artery to tissue in a voxel. Hence, cerebral blood flow (CBF) values estimated from DSC images can be inaccurate. As an alternative, the maximum value of the logarithmic signal ratio (maxDELTA R2*) is occasionally used as an indicator of the CBF in the rat brain [3,4]. To investigate the accuracy of CBF indicated by maxDELTA R2* in the ischemic rat brain, a comparison of the CBF values obtained with continuous arterial spin labeling (CASL) and maxDELTA R2* was performed in an ischemic rat model. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | International Society for Magnetic Resonance in Medicine(ISMRM) 14th Scientific Meeting and Exhibition | |||||
発表年月日 | ||||||
日付 | 2006-05-12 | |||||
日付タイプ | Issued |