WEKO3
アイテム
{"_buckets": {"deposit": "9b351c00-6eeb-4bef-925b-1bb87bef325a"}, "_deposit": {"created_by": 1, "id": "68749", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "68749"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00068749", "sets": ["28"]}, "author_link": ["674670", "674671", "674676", "674667", "674677", "674672", "674668", "674665", "674669", "674666", "674673", "674664", "674674", "674675"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2006-11-04", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We provide a new viewpoint for a fundamental but little investigated problem in positron emission tomography (PET): non-collinearity of annihilation radiation from the human body. The cause of the small angular deviation from 180 deg is described as well as how to evaluate it under a spatially distrib-uted radiation source and a limited acquisition time. An elegant conversion from the photopeak spectrum into the angular distribution is done based on the conservation laws of momentum and energy to avoid problems in the direct measurement. A healthy volunteer study using 18FDG and a Ge semiconductor detector reveals the distribution as a Gaussian function with the FWHM of 0.54 deg. Finally, we calculate the physical limit of FDG-PET spatial resolution.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "IEEE 2006 Nuclear Science Symposium and Medical Imaging Conference", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Shibuya, Kengo"}], "nameIdentifiers": [{"nameIdentifier": "674664", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "674665", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishikido, Fumihiko"}], "nameIdentifiers": [{"nameIdentifier": "674666", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suzuki, Tosikazu"}], "nameIdentifiers": [{"nameIdentifier": "674667", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inadama, Naoko"}], "nameIdentifiers": [{"nameIdentifier": "674668", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "674669", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murayama, Hideo"}], "nameIdentifiers": [{"nameIdentifier": "674670", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "澁谷 憲悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "674671", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 英治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "674672", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "錦戸 文彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "674673", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木 敏和", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "674674", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲玉 直子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "674675", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷 泰賀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "674676", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村山 秀雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "674677", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "A Healthy Volunteer FDG-PET Study on the Limit of the Spatial Resolution due to Annihilation Radiation Non-Collinearity", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A Healthy Volunteer FDG-PET Study on the Limit of the Spatial Resolution due to Annihilation Radiation Non-Collinearity"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/68749", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-11-06"}, "publish_date": "2006-11-06", "publish_status": "0", "recid": "68749", "relation": {}, "relation_version_is_last": true, "title": ["A Healthy Volunteer FDG-PET Study on the Limit of the Spatial Resolution due to Annihilation Radiation Non-Collinearity"], "weko_shared_id": -1}
A Healthy Volunteer FDG-PET Study on the Limit of the Spatial Resolution due to Annihilation Radiation Non-Collinearity
https://repo.qst.go.jp/records/68749
https://repo.qst.go.jp/records/6874922d557c9-fba2-44fb-9861-28735600cc16
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-11-06 | |||||
タイトル | ||||||
タイトル | A Healthy Volunteer FDG-PET Study on the Limit of the Spatial Resolution due to Annihilation Radiation Non-Collinearity | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Shibuya, Kengo
× Shibuya, Kengo× Yoshida, Eiji× Nishikido, Fumihiko× Suzuki, Tosikazu× Inadama, Naoko× Yamaya, Taiga× Murayama, Hideo× 澁谷 憲悟× 吉田 英治× 錦戸 文彦× 鈴木 敏和× 稲玉 直子× 山谷 泰賀× 村山 秀雄 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We provide a new viewpoint for a fundamental but little investigated problem in positron emission tomography (PET): non-collinearity of annihilation radiation from the human body. The cause of the small angular deviation from 180 deg is described as well as how to evaluate it under a spatially distrib-uted radiation source and a limited acquisition time. An elegant conversion from the photopeak spectrum into the angular distribution is done based on the conservation laws of momentum and energy to avoid problems in the direct measurement. A healthy volunteer study using 18FDG and a Ge semiconductor detector reveals the distribution as a Gaussian function with the FWHM of 0.54 deg. Finally, we calculate the physical limit of FDG-PET spatial resolution. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | IEEE 2006 Nuclear Science Symposium and Medical Imaging Conference | |||||
発表年月日 | ||||||
日付 | 2006-11-04 | |||||
日付タイプ | Issued |