WEKO3
アイテム
{"_buckets": {"deposit": "68f4c25a-39fd-4ab7-b7e2-822cb44080de"}, "_deposit": {"created_by": 1, "id": "68634", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "68634"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00068634", "sets": ["28"]}, "author_link": ["673589", "673600", "673601", "673593", "673592", "673596", "673591", "673595", "673598", "673590", "673599", "673597", "673588", "673594", "673587"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2006-09-01", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "To avoid loss of data sampling and sensitivity between detectors in a PET system, it is necessary to fill up scintillation crystals in the region between two PMTs, PMT blind region, and recognize gamma-ray detected location by a special crystal identification technique for the region.\nWe have developed a 2-layer depth of interaction (DOI) detector for the PMT blind. The detector is composed of two layers of scintillation crystal array standing over two PMTs without a light guide plate. Crystal identification, that is 2-layer DOI encoding, is performed by Anger-type calculation of the PMT signals. Because all upper layer crystals and lower crystals in the PMT blind region are not coupled directory to the PMTs, materials between crystals must be chosen to guide scintillation light appropriately from the crystal of detection to the PMT useful area. Not only reflectors, air gap and the translucent film that is expected to pass scintillation light much more than reflector but less than air gap can be the candidates of the material.\nThe basic study to determine proper reflector arrangement was carried out on one position sensitive PMT (PS-PMT) with using distant anodes instead of preparing two PMTs. Lu2(1-x)Y2xSiO5 (LYSO) in dimensions of 1.46 mm x 1.46 mm x 4.5 mm was used as the crystal element and a 256ch flat panel PS-PMT (FP-PMT) was done as the PS-PMT. The FP-PMT has 16 x 16 multi-anodes with 3.04 mm interval. It has 52 mm x 52 mm opening area and 89% of useful area. Since the reflector arrangement was optimized through the basic study, we measured the 2-layer DOI detector performance in the more realistic system with the existence of the PMT blind region made by two FP-PMTs.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "World Congress on Medical Physics and Biomedical Engineering 2006", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Inadama, Naoko"}], "nameIdentifiers": [{"nameIdentifier": "673587", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murayama, Hideo"}], "nameIdentifiers": [{"nameIdentifier": "673588", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsuda, Tomoaki"}], "nameIdentifiers": [{"nameIdentifier": "673589", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "673590", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "673591", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shibuya, Kengo"}], "nameIdentifiers": [{"nameIdentifier": "673592", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishikido, Fumihiko"}], "nameIdentifiers": [{"nameIdentifier": "673593", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "673594", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲玉 直子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673595", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村山 秀雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673596", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "津田 倫明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673597", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷 泰賀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673598", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 英治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673599", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "澁谷 憲悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673600", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "錦戸 文彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673601", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Development of DOI Detector for PMT Blind Region", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of DOI Detector for PMT Blind Region"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/68634", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-09-05"}, "publish_date": "2006-09-05", "publish_status": "0", "recid": "68634", "relation": {}, "relation_version_is_last": true, "title": ["Development of DOI Detector for PMT Blind Region"], "weko_shared_id": -1}
Development of DOI Detector for PMT Blind Region
https://repo.qst.go.jp/records/68634
https://repo.qst.go.jp/records/68634a4986b5b-c984-435d-a8cd-9306f454f3ea
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-09-05 | |||||
タイトル | ||||||
タイトル | Development of DOI Detector for PMT Blind Region | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Inadama, Naoko
× Inadama, Naoko× Murayama, Hideo× Tsuda, Tomoaki× Yamaya, Taiga× Yoshida, Eiji× Shibuya, Kengo× Nishikido, Fumihiko× et.al× 稲玉 直子× 村山 秀雄× 津田 倫明× 山谷 泰賀× 吉田 英治× 澁谷 憲悟× 錦戸 文彦 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | To avoid loss of data sampling and sensitivity between detectors in a PET system, it is necessary to fill up scintillation crystals in the region between two PMTs, PMT blind region, and recognize gamma-ray detected location by a special crystal identification technique for the region. We have developed a 2-layer depth of interaction (DOI) detector for the PMT blind. The detector is composed of two layers of scintillation crystal array standing over two PMTs without a light guide plate. Crystal identification, that is 2-layer DOI encoding, is performed by Anger-type calculation of the PMT signals. Because all upper layer crystals and lower crystals in the PMT blind region are not coupled directory to the PMTs, materials between crystals must be chosen to guide scintillation light appropriately from the crystal of detection to the PMT useful area. Not only reflectors, air gap and the translucent film that is expected to pass scintillation light much more than reflector but less than air gap can be the candidates of the material. The basic study to determine proper reflector arrangement was carried out on one position sensitive PMT (PS-PMT) with using distant anodes instead of preparing two PMTs. Lu2(1-x)Y2xSiO5 (LYSO) in dimensions of 1.46 mm x 1.46 mm x 4.5 mm was used as the crystal element and a 256ch flat panel PS-PMT (FP-PMT) was done as the PS-PMT. The FP-PMT has 16 x 16 multi-anodes with 3.04 mm interval. It has 52 mm x 52 mm opening area and 89% of useful area. Since the reflector arrangement was optimized through the basic study, we measured the 2-layer DOI detector performance in the more realistic system with the existence of the PMT blind region made by two FP-PMTs. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | World Congress on Medical Physics and Biomedical Engineering 2006 | |||||
発表年月日 | ||||||
日付 | 2006-09-01 | |||||
日付タイプ | Issued |