WEKO3
アイテム
{"_buckets": {"deposit": "24fd9b54-d02a-4a8e-807d-25eff7cdf8bd"}, "_deposit": {"created_by": 1, "id": "68577", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "68577"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00068577", "sets": ["28"]}, "author_link": ["673057", "673060", "673053", "673052", "673055", "673061", "673062", "673056", "673051", "673058", "673054", "673059"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2006-07-02", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "放医研中性子発生用加速器システムの現状\n酢屋徳啓、須田充、萩原拓也、濱野毅、宮原信幸、今関等\n放射線医学総合研究所\n\\n放射線医学総合研究所では、平成15年度に中性子発生用加速器システムNeutron exposure Accelerator System for Biological Effect Experiment(NASBEE)を導入した。本システムは、HVEE社製インラインタンデム型静電加速器及び高出力マルチカスプイオン源、NECトーキン製ビーム輸送系及びターゲットシステムで構成されている。\n本システムの特徴は、高フルエンスの速中性子を生物・物理照射室だけでなくSpecific Pathogen Free(特定病原菌未感染:SPF)環境下でマウス、ラット等への照射が可能なことである。\n平成16年3月下旬より加速器本体及び水平ビームライン搬入据付を開始し、HVEE社エンジニアによる調整作業を5月下旬に終了した。また同時期にNECトーキン製垂直ビームラインと中性子照射用ターゲットを含む中性子照射システムの据付を開始し、8月中旬に完了した。平成17年12月施設検査に合格し、重水素イオン4MeV、ターゲット電流400\u0026#61549;Aの条件で、生物照射を行うために必要な中性子線の線量分布測定、LET測定、金属箔の放射化によるエネルギー分布測定を進めた。更に、生体試料への中性子照射量と放射化量の関係、減衰時間測定の実験を行い、平成18年3月から生物照射実験を開始した。今回は中性子線発生用加速器システムの概要やこれまでに発生したトラブル、生物実験専用施設としてのメンテナンスの難しさ、線量分布測定を行った際の問題点とその対応策について発表する。また、これまで行ってきた生物照射実験の概要について報告する。", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "第19回タンデム加速器及びその周辺技術の研究会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "酢屋, 徳啓"}], "nameIdentifiers": [{"nameIdentifier": "673051", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "須田, 充"}], "nameIdentifiers": [{"nameIdentifier": "673052", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "萩原, 拓也"}], "nameIdentifiers": [{"nameIdentifier": "673053", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野, 毅"}], "nameIdentifiers": [{"nameIdentifier": "673054", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原, 信幸"}], "nameIdentifiers": [{"nameIdentifier": "673055", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関, 等"}], "nameIdentifiers": [{"nameIdentifier": "673056", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "酢屋 徳啓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673057", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "須田 充", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673058", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "萩原 拓也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673059", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野 毅", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673060", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原 信幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673061", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関 等", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "673062", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "放医研中性子発生用加速器システムの現状", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "放医研中性子発生用加速器システムの現状"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/68577", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-07-05"}, "publish_date": "2006-07-05", "publish_status": "0", "recid": "68577", "relation": {}, "relation_version_is_last": true, "title": ["放医研中性子発生用加速器システムの現状"], "weko_shared_id": -1}
放医研中性子発生用加速器システムの現状
https://repo.qst.go.jp/records/68577
https://repo.qst.go.jp/records/68577495dd2bf-bcb4-448c-9da6-b8872747f703
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-07-05 | |||||
タイトル | ||||||
タイトル | 放医研中性子発生用加速器システムの現状 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
酢屋, 徳啓
× 酢屋, 徳啓× 須田, 充× 萩原, 拓也× 濱野, 毅× 宮原, 信幸× 今関, 等× 酢屋 徳啓× 須田 充× 萩原 拓也× 濱野 毅× 宮原 信幸× 今関 等 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 放医研中性子発生用加速器システムの現状 酢屋徳啓、須田充、萩原拓也、濱野毅、宮原信幸、今関等 放射線医学総合研究所 \n放射線医学総合研究所では、平成15年度に中性子発生用加速器システムNeutron exposure Accelerator System for Biological Effect Experiment(NASBEE)を導入した。本システムは、HVEE社製インラインタンデム型静電加速器及び高出力マルチカスプイオン源、NECトーキン製ビーム輸送系及びターゲットシステムで構成されている。 本システムの特徴は、高フルエンスの速中性子を生物・物理照射室だけでなくSpecific Pathogen Free(特定病原菌未感染:SPF)環境下でマウス、ラット等への照射が可能なことである。 平成16年3月下旬より加速器本体及び水平ビームライン搬入据付を開始し、HVEE社エンジニアによる調整作業を5月下旬に終了した。また同時期にNECトーキン製垂直ビームラインと中性子照射用ターゲットを含む中性子照射システムの据付を開始し、8月中旬に完了した。平成17年12月施設検査に合格し、重水素イオン4MeV、ターゲット電流400Aの条件で、生物照射を行うために必要な中性子線の線量分布測定、LET測定、金属箔の放射化によるエネルギー分布測定を進めた。更に、生体試料への中性子照射量と放射化量の関係、減衰時間測定の実験を行い、平成18年3月から生物照射実験を開始した。今回は中性子線発生用加速器システムの概要やこれまでに発生したトラブル、生物実験専用施設としてのメンテナンスの難しさ、線量分布測定を行った際の問題点とその対応策について発表する。また、これまで行ってきた生物照射実験の概要について報告する。 |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第19回タンデム加速器及びその周辺技術の研究会 | |||||
発表年月日 | ||||||
日付 | 2006-07-02 | |||||
日付タイプ | Issued |