{"_buckets": {"deposit": "a1b2b87a-45c8-4904-a6fe-7192f09dd6da"}, "_deposit": {"created_by": 1, "id": "68167", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "68167"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00068167", "sets": ["28"]}, "author_link": ["669314", "669315"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2005-09-16", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A low-energy ion deceleration system has been designed and installed in a beam-injection line at the NIRS-930 cyclotron. An advantage of this system, with utilized to the injection line, is to that it allows high-current ion-beam extraction from an ECR-ion source, because it can be operated with a large potential difference between the source and the extractor. The deceleration system is operated at a negative DC-voltage of around -10 kV, which is applied to the extractor and reduced to the ground potential by the decelerator. An electric field in the deceleration system was carefully designed by using a 3-dimensional field simulator. About a five-times intensity increase has been obtained for a 12C4+ beam at the cyclotron exit, as compared with the case where the new system is not used. Design studies of the decelerator as well as the result of a beam test are presented.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "第11回イオン源国際会議(ICIS−05)", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Honma, Toshihiro"}], "nameIdentifiers": [{"nameIdentifier": "669314", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "本間 壽廣", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "669315", "nameIdentifierScheme": "WEKO"}]}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Low-energy Ion Decelerator for an External injection line at the NIRS-930 Cyclotron", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Low-energy Ion Decelerator for an External injection line at the NIRS-930 Cyclotron"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/68167", "pubdate": {"attribute_name": "公開日", "attribute_value": "2005-09-27"}, "publish_date": "2005-09-27", "publish_status": "0", "recid": "68167", "relation": {}, "relation_version_is_last": true, "title": ["Low-energy Ion Decelerator for an External injection line at the NIRS-930 Cyclotron"], "weko_shared_id": -1}
Low-energy Ion Decelerator for an External injection line at the NIRS-930 Cyclotron
https://repo.qst.go.jp/records/68167
https://repo.qst.go.jp/records/681678fccf0a8-3f4a-4d6a-bccd-a73d23ea19a2
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-09-27 | |||||
タイトル | ||||||
タイトル | Low-energy Ion Decelerator for an External injection line at the NIRS-930 Cyclotron | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Honma, Toshihiro
× Honma, Toshihiro× 本間 壽廣 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A low-energy ion deceleration system has been designed and installed in a beam-injection line at the NIRS-930 cyclotron. An advantage of this system, with utilized to the injection line, is to that it allows high-current ion-beam extraction from an ECR-ion source, because it can be operated with a large potential difference between the source and the extractor. The deceleration system is operated at a negative DC-voltage of around -10 kV, which is applied to the extractor and reduced to the ground potential by the decelerator. An electric field in the deceleration system was carefully designed by using a 3-dimensional field simulator. About a five-times intensity increase has been obtained for a 12C4+ beam at the cyclotron exit, as compared with the case where the new system is not used. Design studies of the decelerator as well as the result of a beam test are presented. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第11回イオン源国際会議(ICIS−05) | |||||
発表年月日 | ||||||
日付 | 2005-09-16 | |||||
日付タイプ | Issued |