{"_buckets": {"deposit": "152304d4-7154-4fc5-b498-658767b8abac"}, "_deposit": {"created_by": 1, "id": "67916", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "67916"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00067916", "sets": ["28"]}, "author_link": ["667082", "667083", "667084"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2004-10-22", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The information on the electron densities of bodies is important for the treatment planning of radiotherapy. In order to obtain the electron densities directly, we have developed dual-energy x-ray computed tomography(CT) using synchrotron radiation. It was experimentally proved that the electron density was deduced with about 1 % accuracy from two linear attenuation coefficient. However, the linear attenuation coefficient were measured by a few percent lower than the theoretical ones. We assumed that the less accurate linear attenuation coefficients were caused by the influence of scattered radiation and the non-linearity in the response of the detector. In comparison of the scattered radiation to the simulation results, the\n scattered radiation contributed at the most 0.5 % to the linear attenuation coefficients. Correcting the non-linearity in the detector response functions, the values of linear attenuation coefficient were improved drastically.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "ROME 2004 NSS - MIC - SNPS and RTSD", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tsunoo, Takanori"}], "nameIdentifiers": [{"nameIdentifier": "667082", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "667083", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "角尾 卓紀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "667084", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Measurement of electron density and effective atomic number using dual-energy x-ray CT", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Measurement of electron density and effective atomic number using dual-energy x-ray CT"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/67916", "pubdate": {"attribute_name": "公開日", "attribute_value": "2004-10-28"}, "publish_date": "2004-10-28", "publish_status": "0", "recid": "67916", "relation": {}, "relation_version_is_last": true, "title": ["Measurement of electron density and effective atomic number using dual-energy x-ray CT"], "weko_shared_id": -1}
Measurement of electron density and effective atomic number using dual-energy x-ray CT
https://repo.qst.go.jp/records/67916
https://repo.qst.go.jp/records/67916360acceb-18f0-497a-b4f6-9135f50fdf18
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2004-10-28 | |||||
タイトル | ||||||
タイトル | Measurement of electron density and effective atomic number using dual-energy x-ray CT | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tsunoo, Takanori
× Tsunoo, Takanori× et.al× 角尾 卓紀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The information on the electron densities of bodies is important for the treatment planning of radiotherapy. In order to obtain the electron densities directly, we have developed dual-energy x-ray computed tomography(CT) using synchrotron radiation. It was experimentally proved that the electron density was deduced with about 1 % accuracy from two linear attenuation coefficient. However, the linear attenuation coefficient were measured by a few percent lower than the theoretical ones. We assumed that the less accurate linear attenuation coefficients were caused by the influence of scattered radiation and the non-linearity in the response of the detector. In comparison of the scattered radiation to the simulation results, the scattered radiation contributed at the most 0.5 % to the linear attenuation coefficients. Correcting the non-linearity in the detector response functions, the values of linear attenuation coefficient were improved drastically. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | ROME 2004 NSS - MIC - SNPS and RTSD | |||||
発表年月日 | ||||||
日付 | 2004-10-22 | |||||
日付タイプ | Issued |