WEKO3
アイテム
{"_buckets": {"deposit": "168e465a-6747-449e-a9a2-05693de14977"}, "_deposit": {"created_by": 1, "id": "67716", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "67716"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00067716", "sets": ["28"]}, "author_link": ["665477", "665475", "665479", "665482", "665474", "665481", "665478", "665476", "665480"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2004-02-19", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "[Purpose] We have developed a four-dimensional CT (4D-CT) using continuous rotation of cone-beam x-ray. The maximum field of view for 4D-CT is 128mm at the center of rotation in the longitudinal direction. In order to obtain appropriate estimations of exposure dose, we have measured dose profiles perpendicular to the rotation axis in a lucite cylinder of 320mm diameter.\n[Methods] We have used cylindrical lucite phantom of 320mm diameter and 750mm length. Dose profiles were measured at the center and a peripheral point of 10mm depth. A pin silicon photodiode sensor with 3x3x3mm sensitive region was used as an x-ray detector, which was scanned along longitudinal direction in the phantom for collimator widths of 10, 32, 64, 96 and 128mm.\n[Results] The dose profiles had long tails caused by scattered radiation. For 128 mm collimator width 90% of integral dose was distributed along 350mm length at the center and 220mm at the periphery. Even for 10 mm collimator width 90% of integral dose was distributed along 250mm length at the center and 160mm length at the periphery. [New or breakthrough work to be presented] Before the advent of multi-detector CT CTDI100 was a good estimation of exposure dose, because it expressed approximate integral dose for clinical scan conditions. For 4D-CT employing a variable collimator, the standard CTDI was not a good estimation. In the present work we measured dose profiles for 4D-CT, and showed long tails distributed more than 100mm out of the collimator edge.\n[Conclusion] In order to estimate exposure dose for cone-beam CT such as 4D-CT, it should be recommended to measure integral dose over collimator width plus at least 200mm length.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "SPIE medical imaging", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Endo, Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "665474", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mori, Shinichirou"}], "nameIdentifiers": [{"nameIdentifier": "665475", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsunoo, Takanori"}], "nameIdentifiers": [{"nameIdentifier": "665476", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishizawa, Kanae"}], "nameIdentifiers": [{"nameIdentifier": "665477", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Aoyama, Takahiko"}], "nameIdentifiers": [{"nameIdentifier": "665478", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "遠藤 真広", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "665479", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "665480", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "角尾 卓紀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "665481", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "西澤 かな枝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "665482", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Dose profile measurement of a four-dimensional CT (4D-CT)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Dose profile measurement of a four-dimensional CT (4D-CT)"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/67716", "pubdate": {"attribute_name": "公開日", "attribute_value": "2004-02-20"}, "publish_date": "2004-02-20", "publish_status": "0", "recid": "67716", "relation": {}, "relation_version_is_last": true, "title": ["Dose profile measurement of a four-dimensional CT (4D-CT)"], "weko_shared_id": -1}
Dose profile measurement of a four-dimensional CT (4D-CT)
https://repo.qst.go.jp/records/67716
https://repo.qst.go.jp/records/6771696258577-f949-4f46-8d68-829433419e4d
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2004-02-20 | |||||
タイトル | ||||||
タイトル | Dose profile measurement of a four-dimensional CT (4D-CT) | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Endo, Masahiro
× Endo, Masahiro× Mori, Shinichirou× Tsunoo, Takanori× Nishizawa, Kanae× Aoyama, Takahiko× 遠藤 真広× 森 慎一郎× 角尾 卓紀× 西澤 かな枝 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | [Purpose] We have developed a four-dimensional CT (4D-CT) using continuous rotation of cone-beam x-ray. The maximum field of view for 4D-CT is 128mm at the center of rotation in the longitudinal direction. In order to obtain appropriate estimations of exposure dose, we have measured dose profiles perpendicular to the rotation axis in a lucite cylinder of 320mm diameter. [Methods] We have used cylindrical lucite phantom of 320mm diameter and 750mm length. Dose profiles were measured at the center and a peripheral point of 10mm depth. A pin silicon photodiode sensor with 3x3x3mm sensitive region was used as an x-ray detector, which was scanned along longitudinal direction in the phantom for collimator widths of 10, 32, 64, 96 and 128mm. [Results] The dose profiles had long tails caused by scattered radiation. For 128 mm collimator width 90% of integral dose was distributed along 350mm length at the center and 220mm at the periphery. Even for 10 mm collimator width 90% of integral dose was distributed along 250mm length at the center and 160mm length at the periphery. [New or breakthrough work to be presented] Before the advent of multi-detector CT CTDI100 was a good estimation of exposure dose, because it expressed approximate integral dose for clinical scan conditions. For 4D-CT employing a variable collimator, the standard CTDI was not a good estimation. In the present work we measured dose profiles for 4D-CT, and showed long tails distributed more than 100mm out of the collimator edge. [Conclusion] In order to estimate exposure dose for cone-beam CT such as 4D-CT, it should be recommended to measure integral dose over collimator width plus at least 200mm length. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | SPIE medical imaging | |||||
発表年月日 | ||||||
日付 | 2004-02-19 | |||||
日付タイプ | Issued |