ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

The basic performance evaluation of the first model of 4 Dimensional CT Scanner

https://repo.qst.go.jp/records/67699
https://repo.qst.go.jp/records/67699
17aa93f3-be05-406a-8991-a6697d0ff05a
Item type 会議発表用資料 / Presentation(1)
公開日 2003-12-22
タイトル
タイトル The basic performance evaluation of the first model of 4 Dimensional CT Scanner
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichirou

× Mori, Shinichirou

WEKO 665338

Mori, Shinichirou

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 665339

Endo, Masahiro

Search repository
Tsunoo, Takanori

× Tsunoo, Takanori

WEKO 665340

Tsunoo, Takanori

Search repository
Kandatsu, Susumu

× Kandatsu, Susumu

WEKO 665341

Kandatsu, Susumu

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 665342

Tanada, Shuji

Search repository
Aradate, Hiroshi

× Aradate, Hiroshi

WEKO 665343

Aradate, Hiroshi

Search repository
Saito, Yasuo

× Saito, Yasuo

WEKO 665344

Saito, Yasuo

Search repository
Miyazaki, Hiroaki

× Miyazaki, Hiroaki

WEKO 665345

Miyazaki, Hiroaki

Search repository
Sato, Kazumasa

× Sato, Kazumasa

WEKO 665346

Sato, Kazumasa

Search repository
Matsushita, Satoshi

× Matsushita, Satoshi

WEKO 665347

Matsushita, Satoshi

Search repository
Kusakabe, Masahiro

× Kusakabe, Masahiro

WEKO 665348

Kusakabe, Masahiro

Search repository
森 慎一郎

× 森 慎一郎

WEKO 665349

en 森 慎一郎

Search repository
遠藤 真広

× 遠藤 真広

WEKO 665350

en 遠藤 真広

Search repository
角尾 卓紀

× 角尾 卓紀

WEKO 665351

en 角尾 卓紀

Search repository
神立 進

× 神立 進

WEKO 665352

en 神立 進

Search repository
棚田 修二

× 棚田 修二

WEKO 665353

en 棚田 修二

Search repository
佐藤 一雅

× 佐藤 一雅

WEKO 665354

en 佐藤 一雅

Search repository
松下 聡

× 松下 聡

WEKO 665355

en 松下 聡

Search repository
日下部 正宏

× 日下部 正宏

WEKO 665356

en 日下部 正宏

Search repository
抄録
内容記述タイプ Abstract
内容記述 This work was carried out to evaluate the basic performances for 4 dimensional computed tomography (4D-CT) scanner, which employs continuously rotating cone-beam. The performances were evaluated with the same method as the conventional CT, because the standard method of evaluating 4D-CT has not yet been established, and we think this result was helpful to establish it. 4D-CT scanner can give dynamic volume imaging data continuously and with high-speed. Volume range of the longitudinal length is about 10cm.
It uses a wide-area 2D detector designed on the basis of the present CT technology. The number of elements are 912(channels) x 256(segments), element size is approximately 1mm x 1mm, scanning time is 1sec, and data sampling rate is 900 views (frames)/sec. Feldkamp algorithm was used for reconstruction. We measured six items as follows with stationary phantoms for 4D-CT, and compared them with the results of conventional multi-detector CT. 1.Noise, 2.Distortion, 3.Low contrast and high contrast resolution, 4.Spatial resolution, 5.Artifact, 6.Exposure dose measurement. The results were isotropic except for the evaluation of distortion in which small distortions gradually appeared as coming off the center of phantom in longitudinal direction. We confirmed a uniformity of CT value in longitudinal and transaxial sections. The evaluations of other items were very close to those of conventional CT.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 SPIE
発表年月日
日付 2003-02-19
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:34:44.540826
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3