{"_buckets": {"deposit": "0a78e2d9-4580-4ef1-a347-66de2c6d6564"}, "_deposit": {"created_by": 1, "id": "67458", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "67458"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00067458", "sets": ["28"]}, "author_link": ["663110", "663109"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2003-08-29", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Clinical dose of heavy-ion therapy at HIMAC is defined by physical dose multiplied by RBE. The RBE of heavy ion beam is calculated using LQ model based on experimental survival curve for mono-energetic beams. From this definition, it is very hard to obtain RBE value for heavy ion fields which is not standard mixture of the mono-energetic beams. \n The aim of this work is to establish the method to estimate the clinical dose easily with a tissue equivalent proportional counter. The results for carbon beam of 290MeV/n and 60mm SOBP are reported here.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "World Congress on Medical Physics and Biomedical Engineering 2003", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kase, Yuuki"}], "nameIdentifiers": [{"nameIdentifier": "663109", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加瀬 優紀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "663110", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Estimation of a Clinical Dose of Heavy-Ion Radiotherapy Using a Tissue Equivalent Proportional Counter", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Estimation of a Clinical Dose of Heavy-Ion Radiotherapy Using a Tissue Equivalent Proportional Counter"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/67458", "pubdate": {"attribute_name": "公開日", "attribute_value": "2003-09-03"}, "publish_date": "2003-09-03", "publish_status": "0", "recid": "67458", "relation": {}, "relation_version_is_last": true, "title": ["Estimation of a Clinical Dose of Heavy-Ion Radiotherapy Using a Tissue Equivalent Proportional Counter"], "weko_shared_id": -1}
Estimation of a Clinical Dose of Heavy-Ion Radiotherapy Using a Tissue Equivalent Proportional Counter
https://repo.qst.go.jp/records/67458
https://repo.qst.go.jp/records/67458fc4501db-9032-49c9-92ac-9c5f305a77aa
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2003-09-03 | |||||
タイトル | ||||||
タイトル | Estimation of a Clinical Dose of Heavy-Ion Radiotherapy Using a Tissue Equivalent Proportional Counter | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kase, Yuuki
× Kase, Yuuki× 加瀬 優紀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Clinical dose of heavy-ion therapy at HIMAC is defined by physical dose multiplied by RBE. The RBE of heavy ion beam is calculated using LQ model based on experimental survival curve for mono-energetic beams. From this definition, it is very hard to obtain RBE value for heavy ion fields which is not standard mixture of the mono-energetic beams. The aim of this work is to establish the method to estimate the clinical dose easily with a tissue equivalent proportional counter. The results for carbon beam of 290MeV/n and 60mm SOBP are reported here. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | World Congress on Medical Physics and Biomedical Engineering 2003 | |||||
発表年月日 | ||||||
日付 | 2003-08-29 | |||||
日付タイプ | Issued |