WEKO3
アイテム
{"_buckets": {"deposit": "0acd1866-4ddb-48e6-8f47-534141df1233"}, "_deposit": {"created_by": 1, "id": "66826", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "66826"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00066826", "sets": ["29"]}, "author_link": ["657074", "657075", "657079", "657080", "657077", "657069", "657073", "657081", "657068", "657072", "657070", "657078", "657082", "657067", "657076", "657071"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2018-04-25", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Performance tests of the ITER gyrotrons in QST have been performed to procure eight sets of gyrotron system for ITER Electron Cyclotron Heating and Current Drive (EC H\u0026CD) system. Two ITER gyrotrons was manufactured and these short-pulse tests were completed. Similar beam profiles were identified and 1 MW power was achieved for both #1 and #2 ITER gyrotrons. The long-pulse tests of these gyrotrons are underway and at the present 0.2 MW CW-operation for 300 s has been obtained. The output power of 1 MW with and total efficiency of 48 % was also performed for pulse duration of 10 s.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "Nineteenth International Vacuum Electronics Conference (IVEC 2018) ", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "池田, 亮介"}], "nameIdentifiers": [{"nameIdentifier": "657067", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小田, 靖久"}], "nameIdentifiers": [{"nameIdentifier": "657068", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "梶原, 健"}], "nameIdentifiers": [{"nameIdentifier": "657069", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小林, 貴之"}], "nameIdentifiers": [{"nameIdentifier": "657070", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "寺門, 正之"}], "nameIdentifiers": [{"nameIdentifier": "657071", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高橋, 幸司"}], "nameIdentifiers": [{"nameIdentifier": "657072", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森山, 伸一"}], "nameIdentifiers": [{"nameIdentifier": "657073", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂本, 慶司"}], "nameIdentifiers": [{"nameIdentifier": "657074", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "池田 亮介", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "657075", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小田 靖久", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "657076", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "梶原 健", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "657077", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小林 貴之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "657078", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "寺門 正之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "657079", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高橋 幸司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "657080", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森山 伸一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "657081", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂本 慶司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "657082", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Progress on Performance Test of ITER Gyrotron", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Progress on Performance Test of ITER Gyrotron"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/66826", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-06-12"}, "publish_date": "2018-06-12", "publish_status": "0", "recid": "66826", "relation": {}, "relation_version_is_last": true, "title": ["Progress on Performance Test of ITER Gyrotron"], "weko_shared_id": -1}
Progress on Performance Test of ITER Gyrotron
https://repo.qst.go.jp/records/66826
https://repo.qst.go.jp/records/6682646293346-ed82-435a-9cb6-bbde6e349ece
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-06-12 | |||||
タイトル | ||||||
タイトル | Progress on Performance Test of ITER Gyrotron | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
池田, 亮介
× 池田, 亮介× 小田, 靖久× 梶原, 健× 小林, 貴之× 寺門, 正之× 高橋, 幸司× 森山, 伸一× 坂本, 慶司× 池田 亮介× 小田 靖久× 梶原 健× 小林 貴之× 寺門 正之× 高橋 幸司× 森山 伸一× 坂本 慶司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Performance tests of the ITER gyrotrons in QST have been performed to procure eight sets of gyrotron system for ITER Electron Cyclotron Heating and Current Drive (EC H&CD) system. Two ITER gyrotrons was manufactured and these short-pulse tests were completed. Similar beam profiles were identified and 1 MW power was achieved for both #1 and #2 ITER gyrotrons. The long-pulse tests of these gyrotrons are underway and at the present 0.2 MW CW-operation for 300 s has been obtained. The output power of 1 MW with and total efficiency of 48 % was also performed for pulse duration of 10 s. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Nineteenth International Vacuum Electronics Conference (IVEC 2018) | |||||
発表年月日 | ||||||
日付 | 2018-04-25 | |||||
日付タイプ | Issued |