WEKO3
アイテム
{"_buckets": {"deposit": "ebed7419-b280-4c90-9d8a-1e6e3c9adc3b"}, "_deposit": {"created_by": 1, "id": "66824", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "66824"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00066824", "sets": ["29"]}, "author_link": ["657053", "657052", "657058", "657055", "657054", "657056", "657057", "657059", "657051"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2018-06-07", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Introduction: Recent research has shown alumina-based ceramics TLD (A8, Chibacera Mfg. Co.) is easy to handle and owns a less LET-dependent glow peak which is potential for measurement in heavy charged particle (HCP) therapy beam. However, the sensitivity of is not stable enough for implantation in radiotherapy field. Therefore, a TLD made by chromium-doped alumina (A10, Chibacera Mfg. Co.) was developed to improve the sensitivity.\nPurpose: This study aims to provide basic dosimetric properties of A10. \nMaterial and methods: To obtain the thermal luminescence (TL) efficiency, A10 were irradiated using a 160 MeV/u proton beam, a 150 MeV helium beam, a 290 MeV/u carbon beam, a 400 MeV/u Neon beam and a 500 MeV/u Argon beam. TL efficiency was normalized by a 6MV X-ray. A10 was heated to 400 oC at a heating rate of 0.2 degree per second and the glow curves were read by an in-house developed readout system. To improve the accuracy, the timeline of the readout procedure was consistent for each experiment in the present study.\nResults: The dose to response curve of A10 was linear in the range of 0.5-5 Gy for each beam but the slope was different to each other. The TL efficiency of A10 increased from 0.84 to 1.18 at LET range from 0.5 keV/μm to 13.2 keV/μm and decreased to 0.6 when keV/μm was 197 keV/μm.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "World Congress on Medical Physics \u0026 Biomedical Engineering", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Chang, Weishan"}], "nameIdentifiers": [{"nameIdentifier": "657051", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koba, Yusuke"}], "nameIdentifiers": [{"nameIdentifier": "657052", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shimomura, Risa"}], "nameIdentifiers": [{"nameIdentifier": "657053", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shinsho, Kiyomitsu"}], "nameIdentifiers": [{"nameIdentifier": "657054", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsumoto, Kazuki"}], "nameIdentifiers": [{"nameIdentifier": "657055", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ushiba, Hiroki"}], "nameIdentifiers": [{"nameIdentifier": "657056", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ando, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "657057", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "張 維珊", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "657058", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古場 裕介", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "657059", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Thermal luminescence efficiency of Al2O3:Cr ceramic to heavy charged particle", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Thermal luminescence efficiency of Al2O3:Cr ceramic to heavy charged particle"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/66824", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-06-11"}, "publish_date": "2018-06-11", "publish_status": "0", "recid": "66824", "relation": {}, "relation_version_is_last": true, "title": ["Thermal luminescence efficiency of Al2O3:Cr ceramic to heavy charged particle"], "weko_shared_id": -1}
Thermal luminescence efficiency of Al2O3:Cr ceramic to heavy charged particle
https://repo.qst.go.jp/records/66824
https://repo.qst.go.jp/records/668249ebd3fcd-0598-479a-95f9-437816647026
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-06-11 | |||||
タイトル | ||||||
タイトル | Thermal luminescence efficiency of Al2O3:Cr ceramic to heavy charged particle | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Chang, Weishan
× Chang, Weishan× Koba, Yusuke× Shimomura, Risa× Shinsho, Kiyomitsu× Matsumoto, Kazuki× Ushiba, Hiroki× Ando, Takayuki× 張 維珊× 古場 裕介 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Introduction: Recent research has shown alumina-based ceramics TLD (A8, Chibacera Mfg. Co.) is easy to handle and owns a less LET-dependent glow peak which is potential for measurement in heavy charged particle (HCP) therapy beam. However, the sensitivity of is not stable enough for implantation in radiotherapy field. Therefore, a TLD made by chromium-doped alumina (A10, Chibacera Mfg. Co.) was developed to improve the sensitivity. Purpose: This study aims to provide basic dosimetric properties of A10. Material and methods: To obtain the thermal luminescence (TL) efficiency, A10 were irradiated using a 160 MeV/u proton beam, a 150 MeV helium beam, a 290 MeV/u carbon beam, a 400 MeV/u Neon beam and a 500 MeV/u Argon beam. TL efficiency was normalized by a 6MV X-ray. A10 was heated to 400 oC at a heating rate of 0.2 degree per second and the glow curves were read by an in-house developed readout system. To improve the accuracy, the timeline of the readout procedure was consistent for each experiment in the present study. Results: The dose to response curve of A10 was linear in the range of 0.5-5 Gy for each beam but the slope was different to each other. The TL efficiency of A10 increased from 0.84 to 1.18 at LET range from 0.5 keV/μm to 13.2 keV/μm and decreased to 0.6 when keV/μm was 197 keV/μm. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | World Congress on Medical Physics & Biomedical Engineering | |||||
発表年月日 | ||||||
日付 | 2018-06-07 | |||||
日付タイプ | Issued |