WEKO3
アイテム
{"_buckets": {"deposit": "750659ec-654f-4698-a8e7-f030f919c477"}, "_deposit": {"created_by": 1, "id": "66221", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "66221"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00066221", "sets": ["29"]}, "author_link": ["651677", "651678"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2016-04-15", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "粒子線治療の臨床において治療計画のロバストネス評価や最適化の効率的で簡便な手法が求められている.一般的にロバストネス解析は、時間と手間のかかる作業であり、その解析方法や指標は確立されていない.本研究では、炭素線治療におけるセットアップエラーとレンジエラーに対して高速なDose warping methodを用いたロバストネス解析方法を提案する.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "第111回日本医学物理学会学術大会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "坂間, 誠"}], "nameIdentifiers": [{"nameIdentifier": "651677", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂間 誠", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "651678", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Robustness analysis method with fast estimation of dose uncertainty distributions for carbon-ion therapy treatment planning", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Robustness analysis method with fast estimation of dose uncertainty distributions for carbon-ion therapy treatment planning"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/66221", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-03-23"}, "publish_date": "2017-03-23", "publish_status": "0", "recid": "66221", "relation": {}, "relation_version_is_last": true, "title": ["Robustness analysis method with fast estimation of dose uncertainty distributions for carbon-ion therapy treatment planning"], "weko_shared_id": -1}
Robustness analysis method with fast estimation of dose uncertainty distributions for carbon-ion therapy treatment planning
https://repo.qst.go.jp/records/66221
https://repo.qst.go.jp/records/662213908fbc0-65d4-45df-a67f-64a7f5e9999f
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-03-23 | |||||
タイトル | ||||||
タイトル | Robustness analysis method with fast estimation of dose uncertainty distributions for carbon-ion therapy treatment planning | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
坂間, 誠
× 坂間, 誠× 坂間 誠 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 粒子線治療の臨床において治療計画のロバストネス評価や最適化の効率的で簡便な手法が求められている.一般的にロバストネス解析は、時間と手間のかかる作業であり、その解析方法や指標は確立されていない.本研究では、炭素線治療におけるセットアップエラーとレンジエラーに対して高速なDose warping methodを用いたロバストネス解析方法を提案する. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第111回日本医学物理学会学術大会 | |||||
発表年月日 | ||||||
日付 | 2016-04-15 | |||||
日付タイプ | Issued |