{"_buckets": {"deposit": "3e238510-a667-42d7-9731-88c9f8a770ae"}, "_deposit": {"created_by": 1, "id": "66044", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "66044"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00066044", "sets": ["29"]}, "author_link": ["650319", "650327", "650318", "650324", "650326", "650329", "650325", "650320", "650321", "650322", "650328", "650323"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2016-12-04", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Interventional radiology (IVR) is a medical subspecialty of radiology to realize image-guided surgical procedures using imaging modalities, such as x-ray fluoroscopy. However, skin injuries by prolonged x-ray exposure in duration of procedure have been reported. Therefore, monitoring of skin dose is desired in clinical sites for reduction of excessive x-ray exposure. We are developing a real-time dose distribution monitoring system for the IVR in which only radiolucent materials were in the field of view not to interfere with the IVR procedure. The organic photodiode (OPD) is mainly composed of organic materials, which has good transparency for x-ray. As a result, the detector using the OPDs combined with a plastic scintillator connected to thin flexible cable is expected to have transparency to x-rays. In this paper, therefore, we developed a new detector based on the OPD connected to the thin flexible cable for the real-time monitoring of skin dose distribution in IVR. The device structure of the OPD was plastic scintillator (BC-408, 10 mm × 10 mm × 1 mm)/ IZO (100nm)/ PEDOT: PSS (30 nm) / PCBM: P3HT (200 nm) / Al (70 nm). The size of a sensing area is 6 mm × 4 mm on the plastic scintillator. The readout flexible cable was made of 25 μm polyimide board and 12 μm copper line. The length of the flexible cable is 30 cm and there are three readout electrodes to connect to the OPD electrode. We evaluated performance of the x-ray detectors for with a micro CT (R_mCT2, RIGAKU). As a result, the proposed x-ray detector had a enough transparency to be used in the IVR dosimeter. In addition, we obtained the sufficient detector responses for the various tube current, tube voltage and irradiation angle for x-ray irradiation in real-time with 1 s interval.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "2016IEEE NSS\u0026MIC", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "錦戸, 文彦"}], "nameIdentifiers": [{"nameIdentifier": "650318", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高田, 英治"}], "nameIdentifiers": [{"nameIdentifier": "650319", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野上, 光博"}], "nameIdentifiers": [{"nameIdentifier": "650320", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "前田, 哲哉"}], "nameIdentifiers": [{"nameIdentifier": "650321", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "盛武, 敬"}], "nameIdentifiers": [{"nameIdentifier": "650322", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷, 泰賀"}], "nameIdentifiers": [{"nameIdentifier": "650323", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "錦戸 文彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "650324", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高田 英治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "650325", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野上 光博", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "650326", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "前田 哲哉", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "650327", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "盛武 敬", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "650328", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷 泰賀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "650329", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "X-ray transparent multi-channel dosimeter based on organic photodiodes and plastic scintillators for real-time IVR monitoring", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "X-ray transparent multi-channel dosimeter based on organic photodiodes and plastic scintillators for real-time IVR monitoring"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/66044", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-12-15"}, "publish_date": "2016-12-15", "publish_status": "0", "recid": "66044", "relation": {}, "relation_version_is_last": true, "title": ["X-ray transparent multi-channel dosimeter based on organic photodiodes and plastic scintillators for real-time IVR monitoring"], "weko_shared_id": -1}
X-ray transparent multi-channel dosimeter based on organic photodiodes and plastic scintillators for real-time IVR monitoring
https://repo.qst.go.jp/records/66044
https://repo.qst.go.jp/records/66044448c5382-b82c-4445-8e4c-9e28b58d7c82
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-12-15 | |||||
タイトル | ||||||
タイトル | X-ray transparent multi-channel dosimeter based on organic photodiodes and plastic scintillators for real-time IVR monitoring | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
錦戸, 文彦
× 錦戸, 文彦× 高田, 英治× 野上, 光博× 前田, 哲哉× 盛武, 敬× 山谷, 泰賀× 錦戸 文彦× 高田 英治× 野上 光博× 前田 哲哉× 盛武 敬× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Interventional radiology (IVR) is a medical subspecialty of radiology to realize image-guided surgical procedures using imaging modalities, such as x-ray fluoroscopy. However, skin injuries by prolonged x-ray exposure in duration of procedure have been reported. Therefore, monitoring of skin dose is desired in clinical sites for reduction of excessive x-ray exposure. We are developing a real-time dose distribution monitoring system for the IVR in which only radiolucent materials were in the field of view not to interfere with the IVR procedure. The organic photodiode (OPD) is mainly composed of organic materials, which has good transparency for x-ray. As a result, the detector using the OPDs combined with a plastic scintillator connected to thin flexible cable is expected to have transparency to x-rays. In this paper, therefore, we developed a new detector based on the OPD connected to the thin flexible cable for the real-time monitoring of skin dose distribution in IVR. The device structure of the OPD was plastic scintillator (BC-408, 10 mm × 10 mm × 1 mm)/ IZO (100nm)/ PEDOT: PSS (30 nm) / PCBM: P3HT (200 nm) / Al (70 nm). The size of a sensing area is 6 mm × 4 mm on the plastic scintillator. The readout flexible cable was made of 25 μm polyimide board and 12 μm copper line. The length of the flexible cable is 30 cm and there are three readout electrodes to connect to the OPD electrode. We evaluated performance of the x-ray detectors for with a micro CT (R_mCT2, RIGAKU). As a result, the proposed x-ray detector had a enough transparency to be used in the IVR dosimeter. In addition, we obtained the sufficient detector responses for the various tube current, tube voltage and irradiation angle for x-ray irradiation in real-time with 1 s interval. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 2016IEEE NSS&MIC | |||||
発表年月日 | ||||||
日付 | 2016-12-04 | |||||
日付タイプ | Issued |