WEKO3
アイテム
{"_buckets": {"deposit": "640ce53a-a3b2-443a-bdda-c21a7de96978"}, "_deposit": {"created_by": 1, "id": "64985", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "64985"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00064985", "sets": ["29"]}, "author_link": ["640347", "640346"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2013-04-26", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The X\u0027tal cube is a DOI-PET detector developed in collaboration between Hamamatsu Photonics K.K., Japan and our research team. It consists of a number of multi-pixel photon counters (MPPCs) and a scintillation crystal block segmented 3-dimensionally into cubes. No reflector is inserted in the crystal block so that scintillation light spreads 3-dimensionally inside of the crystal block. The MPPCs are then coupled to all sides of the crystal block. A radiation detected crystal segment can be determined by a simple Anger-type calculation with the MPPC signals. For the crystal block of the X\u0027tal cube, at the first stage, we fabricated a 3-dimensional (3D) array of small cubic crystal elements (array-XC) and later, we developed the laser processing technique to segment inside of a monolithic crystal block 3-dimensionally (laser-XC). In both the array-XC and laser-XC, we attained the identification of 1.0 mm x 1.0 mm x 1.0 mm crystal segments. In this study, we focused on the Anger-type calculation for better segment identification performance. Applying some proportions of weights to the MPPC signal data obtained for the 1.0 mm cubic segment identification, we sought for the weights to get the best performance for each X\u0027tal cube. As a result, we found that the optimal weight proportion was different between the array-XC and laser-XC.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "ソウル大学Jas Sung Lee准教授ラボ訪問および2nd SNU-NIRS Workshop on Nuclear Medicine Imaging Science and Technology参加・発表", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Inadama, Naoko"}], "nameIdentifiers": [{"nameIdentifier": "640346", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲玉 直子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "640347", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Study about position calculation for the DOI-PET detector", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Study about position calculation for the DOI-PET detector"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/64985", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-05-01"}, "publish_date": "2013-05-01", "publish_status": "0", "recid": "64985", "relation": {}, "relation_version_is_last": true, "title": ["Study about position calculation for the DOI-PET detector"], "weko_shared_id": -1}
Study about position calculation for the DOI-PET detector
https://repo.qst.go.jp/records/64985
https://repo.qst.go.jp/records/6498556b2d472-3313-4222-b6dd-92cb1a751e5f
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-05-01 | |||||
タイトル | ||||||
タイトル | Study about position calculation for the DOI-PET detector | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Inadama, Naoko
× Inadama, Naoko× 稲玉 直子 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The X'tal cube is a DOI-PET detector developed in collaboration between Hamamatsu Photonics K.K., Japan and our research team. It consists of a number of multi-pixel photon counters (MPPCs) and a scintillation crystal block segmented 3-dimensionally into cubes. No reflector is inserted in the crystal block so that scintillation light spreads 3-dimensionally inside of the crystal block. The MPPCs are then coupled to all sides of the crystal block. A radiation detected crystal segment can be determined by a simple Anger-type calculation with the MPPC signals. For the crystal block of the X'tal cube, at the first stage, we fabricated a 3-dimensional (3D) array of small cubic crystal elements (array-XC) and later, we developed the laser processing technique to segment inside of a monolithic crystal block 3-dimensionally (laser-XC). In both the array-XC and laser-XC, we attained the identification of 1.0 mm x 1.0 mm x 1.0 mm crystal segments. In this study, we focused on the Anger-type calculation for better segment identification performance. Applying some proportions of weights to the MPPC signal data obtained for the 1.0 mm cubic segment identification, we sought for the weights to get the best performance for each X'tal cube. As a result, we found that the optimal weight proportion was different between the array-XC and laser-XC. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | ソウル大学Jas Sung Lee准教授ラボ訪問および2nd SNU-NIRS Workshop on Nuclear Medicine Imaging Science and Technology参加・発表 | |||||
発表年月日 | ||||||
日付 | 2013-04-26 | |||||
日付タイプ | Issued |