ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

DEVELOPMENT OF A NOVEL OPEN-TYPE PET SYSTEM FOR 3D DOSE VERIFICATION IN CARBON ION THERAPY

https://repo.qst.go.jp/records/64876
https://repo.qst.go.jp/records/64876
5fcef985-4759-4b85-994c-59b19ffc14d1
Item type 会議発表用資料 / Presentation(1)
公開日 2012-12-13
タイトル
タイトル DEVELOPMENT OF A NOVEL OPEN-TYPE PET SYSTEM FOR 3D DOSE VERIFICATION IN CARBON ION THERAPY
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamaya, Taiga

× Yamaya, Taiga

WEKO 639373

Yamaya, Taiga

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 639374

Yoshida, Eiji

Search repository
Kinouchi, Shoko

× Kinouchi, Shoko

WEKO 639375

Kinouchi, Shoko

Search repository
Nakajima, Yasunori

× Nakajima, Yasunori

WEKO 639376

Nakajima, Yasunori

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 639377

Nishikido, Fumihiko

Search repository
Hirano, Yoshiyuki

× Hirano, Yoshiyuki

WEKO 639378

Hirano, Yoshiyuki

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 639379

Tashima, Hideaki

Search repository
Ito, Hiroshi

× Ito, Hiroshi

WEKO 639380

Ito, Hiroshi

Search repository
Haneishi, Hideaki

× Haneishi, Hideaki

WEKO 639381

Haneishi, Hideaki

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 639382

Satou, Shinji

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 639383

Inaniwa, Taku

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 639384

en 山谷 泰賀

Search repository
吉田 英治

× 吉田 英治

WEKO 639385

en 吉田 英治

Search repository
木内 尚子

× 木内 尚子

WEKO 639386

en 木内 尚子

Search repository
中島 靖紀

× 中島 靖紀

WEKO 639387

en 中島 靖紀

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 639388

en 錦戸 文彦

Search repository
平野 祥之

× 平野 祥之

WEKO 639389

en 平野 祥之

Search repository
田島 英朗

× 田島 英朗

WEKO 639390

en 田島 英朗

Search repository
伊藤 浩

× 伊藤 浩

WEKO 639391

en 伊藤 浩

Search repository
羽石 秀昭

× 羽石 秀昭

WEKO 639392

en 羽石 秀昭

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 639393

en 佐藤 眞二

Search repository
稲庭 拓

× 稲庭 拓

WEKO 639394

en 稲庭 拓

Search repository
抄録
内容記述タイプ Abstract
内容記述 Introduction: An open-type PET geometry, "OpenPET" is our original idea to visualize a physi-cally opened space even with a full ring geometry. One of our targets is in-beam PET, which is a method for in situ monitoring of charged particle therapy [1]. We aim to develop the first practical 3D geometry realized, as conventional systems using positron cameras are basically limited to 2D imaging with low sensitivity [2-4]. In our initial idea, the OpenPET had a physically opened field-of-view (FOV) between two detector rings separated by a gap (Figure 1 (a)) [5][6]. Originally, the OpenPET was proposed to provide a stress-less brain imaging device. For a dedicated in-beam PET scanner, this dual-ring OpenPET is a good candidate, but it is not nec-essarily the most efficient geometry because it has a wide FOV (i.e., a gap FOV plus two in-ring FOVs) while only a limited FOV around the irradiation field is required in actual use of in-beam PET. In the last year, therefore, we proposed a single-ring OpenPET (SROP) dedicated for in-beam PET as our 2nd gen-eration geometry [7]. In this paper, we developed a small prototype of the SROP for a proof-of-concept.
\nMaterials and methods: The detector ring of the SROP geometry is the cylinder both ends of which are cut by parallel aslant planes (Figure 1 (b)). The geometry has a gap through which a treatment beam passes. A similar gap can be made simply by slanting a conventional PET scanner as indicated in [8]. Compared with this conventional idea, the proposed geometry has an advantage of compactness so that the beam port can be placed closer to the patient. In addition, the compactness enables efficient design with respect to the sensitivity and the cost (i.e., the number of detectors) [9].
The small SROP prototype consisted of 2 ellipse-shaped detector rings, each of which had 16 detectors. Each ellipse-shaped detector ring had a major axis of 281.6 mm and a minor axis of 207.5 mm. The rings were slanted by 45 deg and staggered to obtain an open space of 74.5 mm width. We carried out initial in-beam phantom imaging tests in the Heavy Ion Medical Accelerator in Chiba (HIMAC) using a 11C beam as well as a 12C beam. PET measurement started at the beginning of the irradiation, and continued for 20 min after the irra-diation.
\nResults: For about 3Gy irradiation, a 6 mm range difference was clearly detected with the 11C beam irradiation. Compared with the 12C beam irradiation, PET images directly corresponding to the distribution of primary particles were obtained in the radioactive beam irradiation.
\nConclusions: Our initial imaging studies showed promising performance of the SROP prototype.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Micro- Mini- and Nano- Dosimetry(MMND2012) & International Prostate Cancer Treatment (IPCT2012) International Workshop
発表年月日
日付 2012-12-09
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:06:34.943999
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3