WEKO3
アイテム
{"_buckets": {"deposit": "ec0ba23b-7357-4fe3-b8d7-2d7a7bd4ac70"}, "_deposit": {"created_by": 1, "id": "64643", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "64643"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00064643", "sets": ["29"]}, "author_link": ["637042", "637049", "637043", "637046", "637040", "637045", "637050", "637039", "637051", "637038", "637041", "637044", "637047", "637052", "637048"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2012-06-13", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Objective: The X\u0027tal cube is our new PET detector, which is being developed to achieve isotropic 3D positioning detectability. The X\u0027tal cube is based on a segmented 3D crystal block for which all surfaces are covered with photo-detectors. We have shown that the X\u0027tal cube can achieve isotropic intrinsic resolution with the Anger-type calculation even at the block edges. In this work, we developed a new one pair prototype system to simulate a ring-type scanner, and evaluated imaging performance of the X\u0027tal cube detector.\nMethods: The developed system consisted of two X\u0027tal cube detectors, two rotating stages, and a 192-channel data acquisition system. The X\u0027tal cube consisted of the LYSO cubic crystal block of (18 mm)3 in which the 3D grids of 2 mm pitch were fabricated by the internal laser processing. 4 x 4 arrays of multi pixel photon counters (MPPCs) were optically coupled to each surface of the crystal block. The detector positions were automatically controlled to simulate a ring-type PET of 14.6 cm in diameter. Data were collected for assumed all detector positions and then a sinogram was obtained. The data were reconstructed using the filtered backprojection.\nResults: We successfully obtained uniform spatial resolution less than 2 mm over the FOV. \nConclusion: We developed one pair prototype system for the X\u0027tal cube detector, and we confirmed its potential for high-resolution imaging", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "SNM2012 Annual Meeting", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yoshida, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "637038", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hirano, Yoshiyuki"}], "nameIdentifiers": [{"nameIdentifier": "637039", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashima, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "637040", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Watanabe, Mitsuo"}], "nameIdentifiers": [{"nameIdentifier": "637041", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishikido, Fumihiko"}], "nameIdentifiers": [{"nameIdentifier": "637042", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murayama, Hideo"}], "nameIdentifiers": [{"nameIdentifier": "637043", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inadama, Naoko"}], "nameIdentifiers": [{"nameIdentifier": "637044", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "637045", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 英治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "637046", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平野 祥之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "637047", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田島 英朗", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "637048", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "錦戸 文彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "637049", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村山 秀雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "637050", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲玉 直子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "637051", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷 泰賀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "637052", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Impact of the X\u0027tal cube detector with isotropic resolution on imaging resolution", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Impact of the X\u0027tal cube detector with isotropic resolution on imaging resolution"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/64643", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-06-28"}, "publish_date": "2012-06-28", "publish_status": "0", "recid": "64643", "relation": {}, "relation_version_is_last": true, "title": ["Impact of the X\u0027tal cube detector with isotropic resolution on imaging resolution"], "weko_shared_id": -1}
Impact of the X'tal cube detector with isotropic resolution on imaging resolution
https://repo.qst.go.jp/records/64643
https://repo.qst.go.jp/records/64643d56caeff-2bea-459b-8deb-8a82887251ea
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-06-28 | |||||
タイトル | ||||||
タイトル | Impact of the X'tal cube detector with isotropic resolution on imaging resolution | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yoshida, Eiji
× Yoshida, Eiji× Hirano, Yoshiyuki× Tashima, Hideaki× Watanabe, Mitsuo× Nishikido, Fumihiko× Murayama, Hideo× Inadama, Naoko× Yamaya, Taiga× 吉田 英治× 平野 祥之× 田島 英朗× 錦戸 文彦× 村山 秀雄× 稲玉 直子× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Objective: The X'tal cube is our new PET detector, which is being developed to achieve isotropic 3D positioning detectability. The X'tal cube is based on a segmented 3D crystal block for which all surfaces are covered with photo-detectors. We have shown that the X'tal cube can achieve isotropic intrinsic resolution with the Anger-type calculation even at the block edges. In this work, we developed a new one pair prototype system to simulate a ring-type scanner, and evaluated imaging performance of the X'tal cube detector. Methods: The developed system consisted of two X'tal cube detectors, two rotating stages, and a 192-channel data acquisition system. The X'tal cube consisted of the LYSO cubic crystal block of (18 mm)3 in which the 3D grids of 2 mm pitch were fabricated by the internal laser processing. 4 x 4 arrays of multi pixel photon counters (MPPCs) were optically coupled to each surface of the crystal block. The detector positions were automatically controlled to simulate a ring-type PET of 14.6 cm in diameter. Data were collected for assumed all detector positions and then a sinogram was obtained. The data were reconstructed using the filtered backprojection. Results: We successfully obtained uniform spatial resolution less than 2 mm over the FOV. Conclusion: We developed one pair prototype system for the X'tal cube detector, and we confirmed its potential for high-resolution imaging |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | SNM2012 Annual Meeting | |||||
発表年月日 | ||||||
日付 | 2012-06-13 | |||||
日付タイプ | Issued |