{"_buckets": {"deposit": "c6ef0c19-4081-441a-ae18-a4d3d0c2dfa4"}, "_deposit": {"created_by": 1, "id": "64343", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "64343"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00064343", "sets": ["29"]}, "author_link": ["634393", "634395", "634394", "634398", "634396", "634388", "634391", "634392", "634399", "634387", "634400", "634389", "634390", "634401", "634397"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2011-10-01", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The X\u0027tal cube is a PET detector we have developed. It has the new structure, which consists of a monolithic scintillation crystal block segmented 3-dimensionally into cubes and semiconductor photo-detectors are coupled on all sides of the crystal block. The crystal segment originating scintillation light can be identified by a simple position calculation with the photo-detector signals. Determination of the crystal segment provides radiation detected location inside the crystal block including depth of interaction (DOI) information which is necessary for a PET scanner to have both high sensitivity and high spatial resolution. We have already showed sufficient performance of the X\u0027tal cube with the prototype using multi-pixel photon counters (MPPCs) for the photo-detectors and a 3-dimensional (3D) array of cubic crystals for the crystal block (array-X\u0027tal cube). Because we newly succeeded to fabricate the 3D array by applying laser processing to a monolithic crystal for easy and reliable assembly, in this study, we evaluated performance of the X\u0027tal cube using the monolithic crystal as the crystal block (laser-X\u0027tal cube). The results showed high crystal identification performance and average energy resolution of 8.6 % for all crystal segments, which are superior to the array-X\u0027tal cube performance.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "第6回日韓医学物理学術合同大会(JKMP)", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Inadama, Naoko"}], "nameIdentifiers": [{"nameIdentifier": "634387", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshioka, Shunsuke"}], "nameIdentifiers": [{"nameIdentifier": "634388", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murayama, Hideo"}], "nameIdentifiers": [{"nameIdentifier": "634389", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishikido, Fumihiko"}], "nameIdentifiers": [{"nameIdentifier": "634390", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "634391", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashima, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "634392", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "634393", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "634394", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲玉 直子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "634395", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉岡 俊祐", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "634396", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村山 秀雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "634397", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "錦戸 文彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "634398", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 英治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "634399", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田島 英朗", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "634400", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷 泰賀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "634401", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Basic study of the PET detector", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Basic study of the PET detector"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/64343", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-10-06"}, "publish_date": "2011-10-06", "publish_status": "0", "recid": "64343", "relation": {}, "relation_version_is_last": true, "title": ["Basic study of the PET detector"], "weko_shared_id": -1}
Basic study of the PET detector
https://repo.qst.go.jp/records/64343
https://repo.qst.go.jp/records/643434f63d81e-988a-4ddc-bbf5-9f914993a883
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-10-06 | |||||
タイトル | ||||||
タイトル | Basic study of the PET detector | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Inadama, Naoko
× Inadama, Naoko× Yoshioka, Shunsuke× Murayama, Hideo× Nishikido, Fumihiko× Yoshida, Eiji× Tashima, Hideaki× Yamaya, Taiga× et.al× 稲玉 直子× 吉岡 俊祐× 村山 秀雄× 錦戸 文彦× 吉田 英治× 田島 英朗× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The X'tal cube is a PET detector we have developed. It has the new structure, which consists of a monolithic scintillation crystal block segmented 3-dimensionally into cubes and semiconductor photo-detectors are coupled on all sides of the crystal block. The crystal segment originating scintillation light can be identified by a simple position calculation with the photo-detector signals. Determination of the crystal segment provides radiation detected location inside the crystal block including depth of interaction (DOI) information which is necessary for a PET scanner to have both high sensitivity and high spatial resolution. We have already showed sufficient performance of the X'tal cube with the prototype using multi-pixel photon counters (MPPCs) for the photo-detectors and a 3-dimensional (3D) array of cubic crystals for the crystal block (array-X'tal cube). Because we newly succeeded to fabricate the 3D array by applying laser processing to a monolithic crystal for easy and reliable assembly, in this study, we evaluated performance of the X'tal cube using the monolithic crystal as the crystal block (laser-X'tal cube). The results showed high crystal identification performance and average energy resolution of 8.6 % for all crystal segments, which are superior to the array-X'tal cube performance. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第6回日韓医学物理学術合同大会(JKMP) | |||||
発表年月日 | ||||||
日付 | 2011-10-01 | |||||
日付タイプ | Issued |