ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

頭頸部腫瘍におけるPETによるメチオニン集積範囲とCT造影範囲の対比検討

https://repo.qst.go.jp/records/63254
https://repo.qst.go.jp/records/63254
892f2bb3-9ad9-4caa-9a98-2c1a00557d17
Item type 会議発表用資料 / Presentation(1)
公開日 2009-09-30
タイトル
タイトル 頭頸部腫瘍におけるPETによるメチオニン集積範囲とCT造影範囲の対比検討
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 大橋, 靖也

× 大橋, 靖也

WEKO 624571

大橋, 靖也

Search repository
吉川, 京燦

× 吉川, 京燦

WEKO 624572

吉川, 京燦

Search repository
長谷部, 充彦

× 長谷部, 充彦

WEKO 624573

長谷部, 充彦

Search repository
石川, 博之

× 石川, 博之

WEKO 624574

石川, 博之

Search repository
佐合, 賢治

× 佐合, 賢治

WEKO 624575

佐合, 賢治

Search repository
田村, 克巳

× 田村, 克巳

WEKO 624576

田村, 克巳

Search repository
鈴木, 和年

× 鈴木, 和年

WEKO 624577

鈴木, 和年

Search repository
佐賀, 恒夫

× 佐賀, 恒夫

WEKO 624578

佐賀, 恒夫

Search repository
神立, 進

× 神立, 進

WEKO 624579

神立, 進

Search repository
辻井, 博彦

× 辻井, 博彦

WEKO 624580

辻井, 博彦

Search repository
大橋 靖也

× 大橋 靖也

WEKO 624581

en 大橋 靖也

Search repository
吉川 京燦

× 吉川 京燦

WEKO 624582

en 吉川 京燦

Search repository
長谷部 充彦

× 長谷部 充彦

WEKO 624583

en 長谷部 充彦

Search repository
石川 博之

× 石川 博之

WEKO 624584

en 石川 博之

Search repository
田村 克巳

× 田村 克巳

WEKO 624585

en 田村 克巳

Search repository
鈴木 和年

× 鈴木 和年

WEKO 624586

en 鈴木 和年

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 624587

en 佐賀 恒夫

Search repository
神立 進

× 神立 進

WEKO 624588

en 神立 進

Search repository
辻井 博彦

× 辻井 博彦

WEKO 624589

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 We objectively compared C-11 methionine (MET) PET/CT and contrast-enhanced (CE) CT images to clarify the difference in diagnostic information using fusion software with a registration algorithm. Eleven patients with adenoid cystic carcinoma (ACC) and twelve patients with malignant melanoma (MM) in head and neck region were studied PET/CT as well as CECT obtained separately. All patients received PET/CT and CECT before carbon ion radiotherapy (CIRT) and fifteen patients received both studies after CIRT. CT image from PET/CT and CECT image were registered automatically by PMOD software based on Mutual Information. And then CT image from PET/CT was replaced with PET image from PET/CT and we got PET/CECT fusion image, and were evaluated according to the four-grade system such as "Matched" with each other, "Embraced " the other, partially "Overlapped" and "Separated" with
each other. Matched-grade,Embraced-grade,verlapped -grade and Separated-grade were
42.1%,39.5%,7.9% and 10.5% in all studies, respectively. Combination of Matched and Embraced-grade was 72.7% studies in ACC and 93.8% studies in MM. Before CIRT, it was 100% in ACC and 91.7% in MM. After CIRT, it was 45.5% in ACC and 100% in MM. MET accumulation and CT enhancement area tended to match before CIRT, but tended to mismatch after CIRT in ACC. It also tended to match mostly both before and after CIRT in MM.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 H20年度HIMAC共同利用研究成果発表会
発表年月日
日付 2009-04-14
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:21:26.605660
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3