WEKO3
アイテム
{"_buckets": {"deposit": "74a82d18-1064-458a-9246-55bf822e99de"}, "_deposit": {"created_by": 1, "id": "62000", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "62000"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00062000", "sets": ["29"]}, "author_link": ["613332", "613333", "613331", "613337", "613335", "613336", "613334", "613330"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2006-12-15", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Internal radiation field of a typical mouse was analyzed by PHITS using a voxel-based model. A mouse was imaged by using the dedicated small-animal CT scanner, in which slice pitch was set at 0.1 mm. Each image with the resolution of 0.02 mm was segmented to construct a voxel-based model by using a computer tool JCDS, which have been applied to process human-head images for 3-dimensional dosimetry in BNCT treatment at the Japan Atomic Energy Agency. Input file for PHITS was prepared from the constructed 3-dimensional voxel-based image data. Distribution of deposition energy inside a mouse was calculated on the segmented images.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "The Japan Taiwan Symposium on Simulation in Medicine", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Satoh, Daiki"}], "nameIdentifiers": [{"nameIdentifier": "613330", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Endo, Akira"}], "nameIdentifiers": [{"nameIdentifier": "613331", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ohmachi, Yasushi"}], "nameIdentifiers": [{"nameIdentifier": "613332", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miyahara, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "613333", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "613334", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "遠藤 章", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "613335", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大町 康", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "613336", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原 信幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "613337", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "PHITS simulation on internal radiation fields at neutron irradiation", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "PHITS simulation on internal radiation fields at neutron irradiation"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/62000", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-01-25"}, "publish_date": "2007-01-25", "publish_status": "0", "recid": "62000", "relation": {}, "relation_version_is_last": true, "title": ["PHITS simulation on internal radiation fields at neutron irradiation"], "weko_shared_id": -1}
PHITS simulation on internal radiation fields at neutron irradiation
https://repo.qst.go.jp/records/62000
https://repo.qst.go.jp/records/62000fbad6840-4ae9-455d-b851-afdfae50aad1
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-01-25 | |||||
タイトル | ||||||
タイトル | PHITS simulation on internal radiation fields at neutron irradiation | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Satoh, Daiki
× Satoh, Daiki× Endo, Akira× Ohmachi, Yasushi× Miyahara, Nobuyuki× et.al× 遠藤 章× 大町 康× 宮原 信幸 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Internal radiation field of a typical mouse was analyzed by PHITS using a voxel-based model. A mouse was imaged by using the dedicated small-animal CT scanner, in which slice pitch was set at 0.1 mm. Each image with the resolution of 0.02 mm was segmented to construct a voxel-based model by using a computer tool JCDS, which have been applied to process human-head images for 3-dimensional dosimetry in BNCT treatment at the Japan Atomic Energy Agency. Input file for PHITS was prepared from the constructed 3-dimensional voxel-based image data. Distribution of deposition energy inside a mouse was calculated on the segmented images. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The Japan Taiwan Symposium on Simulation in Medicine | |||||
発表年月日 | ||||||
日付 | 2006-12-15 | |||||
日付タイプ | Issued |