WEKO3
アイテム
{"_buckets": {"deposit": "4e85b415-ad0f-43e8-a3d5-d9ef82f3ae08"}, "_deposit": {"created_by": 1, "id": "60123", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "60123"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00060123", "sets": ["29"]}, "author_link": ["597798", "597805", "597809", "597797", "597800", "597801", "597799", "597803", "597807", "597806", "597808", "597804", "597802"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2003-11-06", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "National Institute of Radiological Sciences (NIRS) was established in 1957 as a special research institute for research and medical application of radiation, attached to the Science and Technology Agency of Japan. In 1961, NIRS started to use a Van de Graff accelerator (Model KN3000, High Voltage Engineering) for PIXE (Particle Induced X-ray Emission) analysis that was operated as a device for pre-tumor therapy with neutron and finally discarded in 1997. In March 1999, an electrostatic accelerator, HVEE Tandetron, was installed in the Electrostatic Accelerator Building for PIXE analysis. PIXE analysis is a trace analytical method, which has the advantage of simultaneous determination of elemental concentrations in a small specimen without any chemical separation by measuring characteristic X-rays of elements induced by accelerated charged nuclear particles such as protons. [1] \nIn this paper, characteristics of the PIXE system and the new microbeam irradiation facility, Single Particle Irradiation System to Cell (SPICE), which is introduced to our Tandem accelerator are described.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "The 3rd International Symposium on Future Medical Engineering based on BIO-nanotechnology", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Imaseki, Hitoshi"}], "nameIdentifiers": [{"nameIdentifier": "597797", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishikawa, Takahiro"}], "nameIdentifiers": [{"nameIdentifier": "597798", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iso, Hiroyuki"}], "nameIdentifiers": [{"nameIdentifier": "597799", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hamano, Tsuyoshi"}], "nameIdentifiers": [{"nameIdentifier": "597800", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsumoto, Kenichi"}], "nameIdentifiers": [{"nameIdentifier": "597801", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yasuda, Nakahiro"}], "nameIdentifiers": [{"nameIdentifier": "597802", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yukawa, Masae"}], "nameIdentifiers": [{"nameIdentifier": "597803", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関 等", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "597804", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川 剛弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "597805", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野 毅", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "597806", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本 健一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "597807", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安田 仲宏", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "597808", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "湯川 雅枝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "597809", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Introduction of Micro-beam System in NIRS", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Introduction of Micro-beam System in NIRS"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/60123", "pubdate": {"attribute_name": "公開日", "attribute_value": "2003-11-12"}, "publish_date": "2003-11-12", "publish_status": "0", "recid": "60123", "relation": {}, "relation_version_is_last": true, "title": ["Introduction of Micro-beam System in NIRS"], "weko_shared_id": -1}
Introduction of Micro-beam System in NIRS
https://repo.qst.go.jp/records/60123
https://repo.qst.go.jp/records/601233d1f0f35-c8f3-49b8-91c0-82533731513d
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2003-11-12 | |||||
タイトル | ||||||
タイトル | Introduction of Micro-beam System in NIRS | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Imaseki, Hitoshi
× Imaseki, Hitoshi× Ishikawa, Takahiro× Iso, Hiroyuki× Hamano, Tsuyoshi× Matsumoto, Kenichi× Yasuda, Nakahiro× Yukawa, Masae× 今関 等× 石川 剛弘× 濱野 毅× 松本 健一× 安田 仲宏× 湯川 雅枝 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | National Institute of Radiological Sciences (NIRS) was established in 1957 as a special research institute for research and medical application of radiation, attached to the Science and Technology Agency of Japan. In 1961, NIRS started to use a Van de Graff accelerator (Model KN3000, High Voltage Engineering) for PIXE (Particle Induced X-ray Emission) analysis that was operated as a device for pre-tumor therapy with neutron and finally discarded in 1997. In March 1999, an electrostatic accelerator, HVEE Tandetron, was installed in the Electrostatic Accelerator Building for PIXE analysis. PIXE analysis is a trace analytical method, which has the advantage of simultaneous determination of elemental concentrations in a small specimen without any chemical separation by measuring characteristic X-rays of elements induced by accelerated charged nuclear particles such as protons. [1] In this paper, characteristics of the PIXE system and the new microbeam irradiation facility, Single Particle Irradiation System to Cell (SPICE), which is introduced to our Tandem accelerator are described. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The 3rd International Symposium on Future Medical Engineering based on BIO-nanotechnology | |||||
発表年月日 | ||||||
日付 | 2003-11-06 | |||||
日付タイプ | Issued |