WEKO3
アイテム
{"_buckets": {"deposit": "a887e47e-1b36-4dac-aa6c-efb08eb78cad"}, "_deposit": {"created_by": 1, "id": "59545", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "59545"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00059545", "sets": ["29"]}, "author_link": ["592684", "592685", "592686", "592687"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2002-09-28", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have been developing microvolume LET counter in order to measure the three-dimensional LET distribution of the therapeutic heavy ion radiation volumes in the water phantom. With help of the technique of cathode induced carhge readout, this detector has a rectangular (box-shape) sensitive volume of which size is about 1 mm2 and 2mm (depth).", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "The Third Korea-Japan Joint Meeting on Medical Physics and The Second Asia Oceania Congress of Medical Physics", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hirai, Masaaki"}], "nameIdentifiers": [{"nameIdentifier": "592684", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanai, Tatsuaki"}], "nameIdentifiers": [{"nameIdentifier": "592685", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平井 正明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "592686", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金井 達明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "592687", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/59545", "pubdate": {"attribute_name": "公開日", "attribute_value": "2003-01-29"}, "publish_date": "2003-01-29", "publish_status": "0", "recid": "59545", "relation": {}, "relation_version_is_last": true, "title": ["Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam"], "weko_shared_id": -1}
Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam
https://repo.qst.go.jp/records/59545
https://repo.qst.go.jp/records/59545bdebea9d-e330-4f28-a3a5-43604bed450d
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2003-01-29 | |||||
タイトル | ||||||
タイトル | Development of Microvolume LET Counter for Therapeutic Heavy Ion Beam | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hirai, Masaaki
× Hirai, Masaaki× Kanai, Tatsuaki× 平井 正明× 金井 達明 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We have been developing microvolume LET counter in order to measure the three-dimensional LET distribution of the therapeutic heavy ion radiation volumes in the water phantom. With help of the technique of cathode induced carhge readout, this detector has a rectangular (box-shape) sensitive volume of which size is about 1 mm2 and 2mm (depth). | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The Third Korea-Japan Joint Meeting on Medical Physics and The Second Asia Oceania Congress of Medical Physics | |||||
発表年月日 | ||||||
日付 | 2002-09-28 | |||||
日付タイプ | Issued |