WEKO3
アイテム
{"_buckets": {"deposit": "bd16d227-a008-40d8-8108-96800e1b5b05"}, "_deposit": {"created_by": 1, "id": "59480", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "59480"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00059480", "sets": ["29"]}, "author_link": ["592041", "592042", "592038", "592039", "592045", "592043", "592040", "592044"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2002-11-25", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In March 1999, we installed an accelerator in the Electrostatic Accelerator Building for PIXE (Particle Induced X-ray Emission) analysis. The accelerator facility incorporates three beam lines for conventional, in-air and scanning microbeam PIXE analysis. The scanning microbeam PIXE analysis system provides the ability of multi-elemental mapping over sample areas up to 2 x 2mm area with spatial resolutions routinely at 1 micro meter. The scheduled operation of this facility started in April 2000. The result of beam resolution tests carried out in 2001 are as follows: For Scanning Transmission Ion Microscopy (STIM), the estimated beam size is 100 x 200 nm. For PIXE operation at 50 pA of beam current, the estimated best spot size is 0.4 x 0.6 micro meters. The micro-beam apparatus is being used for research into the elemental distribution of small biological samples such as biological cells and tissue.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "21世紀連合シンポジウム-科学技術と人間", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "今関, 等"}], "nameIdentifiers": [{"nameIdentifier": "592038", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "湯川, 雅枝"}], "nameIdentifiers": [{"nameIdentifier": "592039", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川, 剛弘"}], "nameIdentifiers": [{"nameIdentifier": "592040", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野, 毅"}], "nameIdentifiers": [{"nameIdentifier": "592041", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関 等", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "592042", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "湯川 雅枝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "592043", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川 剛弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "592044", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野 毅", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "592045", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "PIXE(荷電粒子励起エックス線)分析用加速器システム", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "PIXE(荷電粒子励起エックス線)分析用加速器システム"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/59480", "pubdate": {"attribute_name": "公開日", "attribute_value": "2002-12-16"}, "publish_date": "2002-12-16", "publish_status": "0", "recid": "59480", "relation": {}, "relation_version_is_last": true, "title": ["PIXE(荷電粒子励起エックス線)分析用加速器システム"], "weko_shared_id": -1}
PIXE(荷電粒子励起エックス線)分析用加速器システム
https://repo.qst.go.jp/records/59480
https://repo.qst.go.jp/records/594804d0d59fb-9f23-44ef-99a5-d95ec3fd80e8
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2002-12-16 | |||||
タイトル | ||||||
タイトル | PIXE(荷電粒子励起エックス線)分析用加速器システム | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
今関, 等
× 今関, 等× 湯川, 雅枝× 石川, 剛弘× 濱野, 毅× 今関 等× 湯川 雅枝× 石川 剛弘× 濱野 毅 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In March 1999, we installed an accelerator in the Electrostatic Accelerator Building for PIXE (Particle Induced X-ray Emission) analysis. The accelerator facility incorporates three beam lines for conventional, in-air and scanning microbeam PIXE analysis. The scanning microbeam PIXE analysis system provides the ability of multi-elemental mapping over sample areas up to 2 x 2mm area with spatial resolutions routinely at 1 micro meter. The scheduled operation of this facility started in April 2000. The result of beam resolution tests carried out in 2001 are as follows: For Scanning Transmission Ion Microscopy (STIM), the estimated beam size is 100 x 200 nm. For PIXE operation at 50 pA of beam current, the estimated best spot size is 0.4 x 0.6 micro meters. The micro-beam apparatus is being used for research into the elemental distribution of small biological samples such as biological cells and tissue. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 21世紀連合シンポジウム-科学技術と人間 | |||||
発表年月日 | ||||||
日付 | 2002-11-25 | |||||
日付タイプ | Issued |